*Drill on centerline 1¼" (3.1 cm) from rear wall for gas supply 
line.
**Gas lines must be installed within the shaded area to ensure 
proper alignment of this oven with cabinets.
***Recessed electrical plugs must be installed within the shaded 
area to ensure proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 
cabinet is covered by not less than 
¹⁄₄" (0.64 cm) flame retardant 
millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an uncovered wood or metal cabinet.
Electrical Requirements - U.S.A. Only
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path and wire gauge are in accordance with local 
codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician if you are in doubt as to whether the 
appliance is properly grounded. Do not modify the power supply 
cord plug. If it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located behind 
the control panel. Refer to the figures in “Product 
Dimensions” in the “Location Requirements” section.
This range is manufactured with the neutral terminal 
connected to the cabinet. Use a 3-wire, UL listed, 40- or 
50-amp power supply cord (pigtail) (see the following Range 
Rating chart). If local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 
40 or 50 amps and investigated for use with ranges.
*The NEC calculated load is less than the total connected load 
listed on the model/serial/rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.9 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker 
box (or fused disconnect) through flexible or nonmetallic 
sheathed, copper or aluminum cable. See the “Electrical 
Connection - U.S.A. Only” section.
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).
Wire sizes and connections must conform with the rating of 
the range.
The wiring diagram is located on the back of the range or in a 
clear plastic bag.
A. 18" (45.7 cm) upper cabinet to countertop
B. 13" (33.0 cm) upper cabinet depth
C. 30" (76.2 cm) min. opening width
D. For minimum clearance to the top of the cooktop, see NOTE.
E. 30" (76.2 cm) min. opening width
F. 3" (7.6 cm) min. clearance from both sides of the range to the side 
wall or other combustible material.
G. Cabinet door or hinges should not extend into the cutout.
H. 3" (7.6 cm) distance from wall
I. 1
¹⁄₂
" (3.8 cm) min. from right side cabinet
J. 8" (20.3 cm) width
K. 7" (17.8 cm) min. from floor
L. 2" (5.1 cm) min. from floor
B
D
C
E
A
F
G
H
I
J
K
L
8½"
(21.6 cm)
14"
(35.6 cm)
8½" (21.6 cm)**
gas line location
1½" 
(3.8 cm)
1¼"*
(3.1 cm)
2¼" (5.7 cm)
***
L
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.8 - 16.5 KW
16.6 - 22.5 KW
7.8 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50