Cisco Systems DOC-7812945= 사용자 설명서
A-9
Cisco WAN Manager User’s Guide
Version 10.5, Part Number 78-12945-01 Rev. D0, August 2003
Appendix A Internet Connectivity
PNNI Link
Step 5
Manually configure mapping for MGX 8850 Release 2:
map-list atm
ip 172.29.24.190 atm-nsap 47.0091.8100.0000.1010.1010.1010.1010.1010.1010.10
Step 6
Manually set up IP route table entries for MGX 8850 Release 2:
ip route 172.29.24.190 255.255.255.0 172.29.23.118
Step 7
Make sure IP routing enabled:
ip routing
PNNI Link
You must create a PNNI link between the MGX 8850 Release 2 node (for the node which is physically
connected to the router) and the router. To create a PNNI link, complete the following described below:
connected to the router) and the router. To create a PNNI link, complete the following described below:
From the AXSM
Step 1
Create a UNI port,
popeye10.6.AXSM.a > addport 1 1.1 48000 48000 6 1
Step 2
Create a partition,
popeye10.6.AXSM.a > addpart 1 1 2 1000000 1000000 1000000 1000000 1 255 33 65535 100 1000
From the PXM
Step 1
Display the PNNI ports,
popeye10.7.PXM45.a > dsppnports
Step 2
Check whether the port is up and normal
PortId IF status Admin status ILMI state Total Activeconns
7.35 up up Undefined 0
7.36 up up Undefined 0
7.37 up up Undefined 0
7.38 up up Undefined 0
6:1.1:1 up up UpAndNormal 1
Step 3
If the port is displayed, then do the following:
popeye10.7.PXM45.a > dnpnport 6:1.1:1
popeye10.7.PXM45.a > cnfpnportsig 6:1.1:1 -univer uni31
popeye10.7.PXM45.a > uppnport 6:1.1:1
popeye10.7.PXM45.a >
addaddr 6:1.1:1 47.0091.8100.0000.1010.1010.1010.1010.1010.1010.10 160