Cisco Systems DOC-7812945= 사용자 설명서

다운로드
페이지 298
A-9
Cisco WAN Manager User’s Guide
Version 10.5, Part Number 78-12945-01 Rev. D0, August 2003
Appendix A      Internet Connectivity
PNNI Link
Step 5
Manually configure mapping for MGX 8850 Release 2: 
map-list atm
ip 172.29.24.190 atm-nsap 47.0091.8100.0000.1010.1010.1010.1010.1010.1010.10
Step 6
Manually set up IP route table entries for MGX 8850 Release 2: 
ip route 172.29.24.190 255.255.255.0 172.29.23.118
Step 7
Make sure IP routing enabled: 
ip routing
PNNI Link
You must create a PNNI link between the MGX 8850 Release 2 node (for the node which is physically 
connected to the router) and the router. To create a PNNI link, complete the following described below: 
From the AXSM
Step 1
Create a UNI port,
popeye10.6.AXSM.a > addport 1 1.1 48000 48000 6 1
Step 2
Create a partition,
popeye10.6.AXSM.a > addpart 1 1 2 1000000 1000000 1000000 1000000 1 255 33 65535 100 1000
From the PXM
Step 1
Display the PNNI ports, 
popeye10.7.PXM45.a > dsppnports
Step 2
Check whether the port is up and normal
PortId         IF status         Admin status       ILMI state       Total Activeconns
7.35           up                up                 Undefined        0       
7.36           up                up                 Undefined        0       
7.37           up                up                 Undefined        0 
7.38           up                up                 Undefined        0 
6:1.1:1        up                up                 UpAndNormal      1       
Step 3
If the port is displayed, then do the following: 
     popeye10.7.PXM45.a > dnpnport 6:1.1:1
     popeye10.7.PXM45.a > cnfpnportsig 6:1.1:1 -univer uni31
     popeye10.7.PXM45.a > uppnport 6:1.1:1
popeye10.7.PXM45.a > 
        addaddr  6:1.1:1 47.0091.8100.0000.1010.1010.1010.1010.1010.1010.10  160