Wolf CMJ34 전단

다운로드
페이지 2
NOTE:  In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-39080 (04-07)
Model CMJ Series
Gas Infrared Cheesemelter
INSTALLATION REQUIREMENTS:
1.  A  gas  pressure  regulator  sized  for  this  unit  is  included.  
Natural Gas 5.0" W.C. Propane Gas 10.0" W.C.
2.  Gas line connecting to appliance must be ¾" diameter or 
larger. If flexible connectors are used, the inside diameter 
must be the same as the ¾" iron pipe.
3.  An  adequate  ventilation  system  is  required  for  commer-
cial  cooking  equipment.  Information  may  be  obtained  
by  writing  to  the  National  Fire  Protection Association,  
1 Batterymarch Park, Quincy, MA 02169, www.NFPA.org. 
When writing, refer to NFPA No. 96.
4.  These units are manufactured for installation in accordance 
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American 
Gas  Association,  Accredited  Standards  Committee  Z223 
 
MODEL 
 
 
 
NUMBER OF 
TOTAL 
APPROX. SHP. 
 
NO. 
WIDTH 
DEPTH 
HEIGHT 
BURNERS 
BTU/hr. 
WT. (lbs./kg)
 
CMJ24 
24" 
20½" 
19¹⁄₁₆" 
18,000 
106/48
 
CMJ34 
34" 
20½" 
19¹⁄₁₆" 
24,000 
159/72
 
CMJ36 
36" 
20½" 
19¹⁄₁₆" 
24,000 
159/72
 
CMJ48 
48" 
20½" 
19¹⁄₁₆" 
36,000 
212/95
 
CMJ60 
60" 
20½" 
19¹⁄₁₆" 
42,000 
265/119
 
CMJ72 
72" 
20½" 
19¹⁄₁₆" 
48,000 
318/143
@  400N.  Capital  St.  NW,  Washington,  DC  20001,  or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.
 
 
NOTE: In the Commonwealth of Massachusetts
 
All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped with a damper or with a power 
means of exhaust shall comply with 248 CMR. 
5.  Clearances:
 
 
Combustible 
Non-Combustible
 
Rear 
2" 
0"
 
Sides 
20" 
0"
 
Bottom 
10" 
4"