Panasonic AW-PH650N 사용자 설명서

다운로드
페이지 44
25
Connections
Concerning the connectors inside the housing
The connectors shown in the figure below are provided inside the housing. Check the connection instructions for each of the 
cameras concerned, and connect them.
 
 
 LENS I/F (1) connector
This is provided for controlling the zooming and focusing 
of the motorized lens unit. Connect the remote (zoom/
focus) control cable of the motorized lens unit to this 
connector.
 ND/EXT connector
This is provided for controlling the ND filter or lens 
extender of the motorized lens unit. Connect it when 
using a motorized lens unit with an ND filter or lens 
extender function.
 LENS I/F (2) connector
Connect this when using a Canon IAS lens, WAS lens or 
VAS lens or a Fujinon RD lens.
Check that the lens can be stowed inside the housing, 
because some lenses cannot be stowed according to 
the position of the connector on the bottom the lens.
  LENS I/F (2) control selector switch 
[Shipment setting: Fujinon]
Set the LENS I/F (2) control selector switch to the 
position that corresponds to the lens used.
Fujinon:  RD lens made by Fujinon
Canon:   IAS lens, WAS lens or VAS lens made by 
Canon
 CAMERA I/F connector
This is provided for controlling a camera. Connect it to 
the camera REMOTE connector using the camera cable 
supplied with the AW-PH650.
  Camera control selector switch  
[Shipment setting: HRP]
Camera
Switch setting
Convertible camera
HRP
AK-HC900 series
HRP
AK-HC1500
Control exercised 
from HRP150
Control exercised 
from CB400
HRP
CB400
•  Use this switch at the HRP setting when using a 
convertible camera. It cannot be controlled from the 
AK-HRP150. Use a camera controller for a convertible 
camera.
•   Similarly, use the switch at the HRP setting when using 
the AK-HC900 series. It cannot be controlled from the 
AW-CB400. Use the AK-HRP150.
•   When using the AK-HC1500, there is a need to select 
the switch using the camera controller used. 
Set the switch to the HRP setting when exercising 
control from the AK-HRP150 or at the CB400 setting 
when exercising control from the AW-CB400.