Sunrise Global CM250 IP 사용자 설명서
PC-IP Software
User’s Manual
64
VIEW SCAN SAVED FILE
When the Scan icon is in color, it means that the current file is
a Scan saved file and can be viewed and analyzed by clicking on
the icon. When the icon is selected, a window (Figure 5-4)
displays the Scan saved data. The Technician name, type of file
and File Name and Location will be displayed in the upper right
area of the screen. The location indicates the current set of Limits
criteria used for the Pass/Fail analysis: Set-Top, Ground Block,
Tap. The display automatically configures itself to best display
the type of signal that is being measured, according to the
Channel Table data and measurement levels.
a Scan saved file and can be viewed and analyzed by clicking on
the icon. When the icon is selected, a window (Figure 5-4)
displays the Scan saved data. The Technician name, type of file
and File Name and Location will be displayed in the upper right
area of the screen. The location indicates the current set of Limits
criteria used for the Pass/Fail analysis: Set-Top, Ground Block,
Tap. The display automatically configures itself to best display
the type of signal that is being measured, according to the
Channel Table data and measurement levels.
Scan is an automated test mode with a quick and
comprehensive set of tests on all of the channels in the
currently active channel table. The Install Profiler steps
through the channel table and measures the video and audio
or digital carrier level of each active channel, displays the
measurements graphically on the screen and builds a data
table with the measurement results in tabular form. The
measurement results are also compared to the Limits criteria
stored in memory in the Limits Setup screen. See the Limits
Setup section. Measurements, which fall within the Limits
criteria, will be displayed in their normal colors; measurements
outside of the Limits criteria will be displayed in red. Set the
appropriate Location prior to initiating Scan so that the
appropriate Limits criteria is used to qualify the test results.
comprehensive set of tests on all of the channels in the
currently active channel table. The Install Profiler steps
through the channel table and measures the video and audio
or digital carrier level of each active channel, displays the
measurements graphically on the screen and builds a data
table with the measurement results in tabular form. The
measurement results are also compared to the Limits criteria
stored in memory in the Limits Setup screen. See the Limits
Setup section. Measurements, which fall within the Limits
criteria, will be displayed in their normal colors; measurements
outside of the Limits criteria will be displayed in red. Set the
appropriate Location prior to initiating Scan so that the
appropriate Limits criteria is used to qualify the test results.