Administrative Tasks
1-20
Getting Started
601354 Rev A
GUI 
Environment
The GUI environment variables in the following table can be 
modified, as required, to define specific GUI parameters. These 
variables should not be modified unless directed by ATAC 
personnel. VolServ must be cycled for the changes to become 
effective. 
ARCDISP_IPC_WAIT_
TIME
1
The amount of time in seconds between 
each retry that the archive dispatcher waits 
before trying to connect to the VolServ 
process. Increase this value if syslog 
message V360 with an error of 9 is 
received.
Variable Name
Default
Description
Variable Name
Default
Description
VS_DEF_PRIORITY
15
The request priority for operations that do 
not have a variable priority scale for setting 
the priority. 
VS_MAX_LIST_LENGTH
1000
The maximum number of items that can 
populate the media list for a media filter. If 
more than this number are selected, the 
filter search fails and asks for a more 
narrow description of the media IDs 
required.
VS_MAX_TEXT_LENGTH
20000
The maximum number of characters 
allowed to fill a status window. Once 
reached, the status messages are 
removed in FIFO order. If this number is 
too large, system performance is 
degraded.
VSWIN_IPC_RETRIES
3
The number of times 
vsadm
 attempts to 
connect over IPC.
VSWIN_IPC_RETRY_TIME
180
Number of seconds 
vsadm
 attempts to 
reconnect to processes over IPC after a 
connection to those processes is lost.