Adiministrative Tasks
601354 Rev A
Start-up and Shutdown
2-3
Star
t-up and 
Shutdo
wn
Start-Up 
Equipment 
This chapter contains information to power-up the hardware 
components of a VolServ system and information and 
procedures to start-up and shutdown VolServ.
Perform start-up of all equipment in accordance with the 
appropriate host computer, archive, and tape drive manufacturer 
manuals. 
There is no required sequence of power application for the 
hardware components of the VolServ system with one 
exception; power must be applied to the ER90 transport units 
before power is applied to the ER90 electronic units. 
Start-Up 
VolServ 
Archive configuration can be performed from the Volume 
Server System
 Console without VolServ running. Note, 
however, that VolServ software initialization terminates if an 
archive is being reconfigured when VolServ software 
initialization is begun. 
The user initializing VolServ must have root or vsadm 
privileges.
Step 1.
Login as vsadm, either remotely or locally, on the 
VolServ host computer.
Step 2.
Type volserv or volserv -s at the command line.
Note
Remote login requires that the environment where 
the command is executed be properly set up as 
described in the Installing VolServ book for the 
appropriate host platform.
hostnamevolserv