17
SECTION 4
TROUBLESHOOTING
4.1 LIGHT INDICATORS
The freezer has two lights that will alert the user if a problem occurs: an ADD MIX light and a Diagnostic Light.
The ADD MIX light will flash to alert the operator to a low mix condition. It does so by monitoring the mix level in the
hopper. When the ADD MIX light is flashing, refill hopper immediately.
The Diagnostic Light will flash if an error occurs. Refer to the chart below for details.
4.2 TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
REMEDY
Freezer does not 
run.
1. Power to freezer is off.
2. Blown fuse or tripped circuit.
3. Freeze-up (auger will not turn).
4. High pressure cut-out tripped.
5. Front door not in place.     
1. Supply power to freezer.
2. Replace or reset.
3. Turn CLEAN-OFF-ON switch to OFF (middle) 
position for 15 minutes, then restart.
4. Wait until automatic reset for freezer to start.
5. Assemble front door in place.
Freezer will not 
shut off.
1. Drive belt failure.
2. Consistency temperature setting is too 
firm.
3. Refrigeration problem.
1. Replace drive belt.
2. Turn Consistency Adjustment knob counter-
clockwise.
3. Check system. (Call distributor for service)
Product is too firm.
1. Consistency temperature setting is too 
firm.                                                       
1. Turn Consistency Adjustment knob counter-
clockwise.
Indication
On
One Blink
Two Blinks
Three Blinks
Conditions
Defrost Mode
Torque is not 
met after 20 
minutes 
(22 minutes for 
shake)
Drive current is not sensed
Freezer left in clean 
mode for over 20 
minutes
Self 
Correction
N/A
N/A
The freezer attempts to sense drive 
current with a 3 second pre-stir.  If current 
is sensed, the freezer will return to normal 
operation.  If current is not sensed, the 
freezer will wait 7 minutes and try to 
sense current with another 3 second pre-
stir.  After the third attempt, the 
compressor will run on timers.
N/A
Operation
Every 7 minutes 
the auger will 
run for 90 
seconds.
Timers
Timers
Off
Corrective 
Action
N/A
Contact Service 
Technician
Contact Service Technician
Turn CLEAN-OFF-ON 
switch to OFF 
(middle) position then 
turn the switch to ON.