230 Volt Operation 
As received from the factory, the DT65 
Dovetailer is designed to run on 230 volt power 
only. You may either connect a UL/CSA listed 
230V plug (similiar to the one shown in Figure 6) 
or “hard-wire” the machine directly to a control 
panel. If hard-wired to a panel, make sure a 
disconnect is available for the operator. The 
dovetailer must comply with all local and 
national codes after being wired. 
1.  If it is to be hard-wired, make sure the fuses 
have been removed or the breakers have 
been tripped in the circuit to which the 
dovetailer will be connected. Place a 
warning placard on the fuse holder or circuit 
breaker to prevent it being turned on while 
the machine is being wired. 
2.  Refer to “Electrical Connections” on page 36 
for connecting the motor leads. 
3.  The Dovetailer with a 230 volt plug should 
only be connected to an outlet having the 
same configuration. No adapter is available 
or should be used with the 230 volt plug. 
Extension cords 
If an extension cord is necessary, make sure the 
cord rating is suitable for the amperage listed on 
the machine’s motor plate. An undersized cord 
will cause a drop in line voltage resulting in loss 
of power and overheating. 
Use the chart in Figure 7 as a general guide in 
choosing the correct size cord. If in doubt, use 
the next heavier gauge. The smaller the gauge 
number, the heavier the cord.  
Air Connection 
Connect the air supply hose to the coupling on 
the air unit (Figure 8). The air is turned ON by 
rotating the valve lever 90 degrees 
counterclockwise (until it is parallel with the 
hose), and turned OFF by rotating the valve 
lever 90 degrees clockwise. 
  Even after the air has been 
turned off to the machine, there may be 
residual air inside the lines, and the 
clamping cylinders can still provide a hazard 
to fingers. After shutting off the air, always 
bleed residual air from the system by 
pushing the relief valve pin at the bottom of 
the air cup, shown in Figure 8. Keep the 
relief valve open until all air in the system 
has been removed. 
 
 
Figure 6 
 
 
 
 
 
Recommended Gauges (AWG) of Extension Cords 
Amps 
Extension Cord Length * 
25 
feet 
50 
feet 
75 
feet 
100 
feet 
150 
feet 
200 
feet 
16 16 16 14 12 12 
to 
8  16 16 14 12 10 NR 
to 
12  14 14 12 10 NR NR 
12 
to 
15 12 12 10 10 NR NR 
15 to 20 
10 
10 
10 
NR 
NR 
NR 
21 
to 
30  10  NR NR NR NR NR 
*based on limiting the line voltage drop to 5V at 150% of the 
rated amperes. 
NR: Not Recommended. 
Figure 7 
 
 
Figure 8