Alto-Shaam 714ESG 사용자 설명서

다운로드
페이지 33
COMBITOUCH
TM
 ESG SERIES • GAS INSTALLATION MANUAL • 22.
INSTALLATION
1-1/2” (41mm) 
diameter connection 
required
Condensate Pan 
Clean Out
The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is supplied 
with a 1-1/2-inch (41mm) NPT thread.
A union is required. Install a 1-1/2-inch (41mm) diameter connection, drain line and clamp into place. 
The drain line must always be a positive gradient 
away from the Combitherm oven and not more 
than 12-inches (305mm) before an air gap.
NOTE: 
  In the U.S.A., this equipment is to be 
installed to comply with the Basic Plumbing 
Code of the Building Offi cials and Code 
Administrators International, Inc. [BOCA], 
and the Food Service Sanitation Manual of 
the Food & Drug Administration [FDA].
If several units are to be connected to one drain 
pipe, the dimensions of the pipe must be sufficient 
to allow an unobstructed water drain system.
WATER VALVE
WATER DRAINAGE
NOTE:
THE SHUT-OFF VALVE 
MUST BE IN THE OPEN POSITION 
WHEN THE OVEN IS BEING USED.
1-1/2" (41mm) diameter NPT
at back of oven
WASTE PIPE
1-1/2" to 2" minimum diameter
(c. 38mm to 51mm)
2" (51mm)
Air Gap
1-1/2” (41mm) diameter 
NPT at back of oven
WASTE PIPE
1-1/2” to 2” minimum diameter
(c. 38mm to 51mm)
2” (51mm) 
Air Gap
SHUT-OFF VALVE SHOWN 