E. Float Switch Check and Cleaning
FS is used to determine that there is sufficient water in the water tank after the 1-min. 
fill cycle and after each harvest cycle. FS is also used to determine that the appropriate 
volume of water has been converted into ice before switching out of the freeze cycle. No 
adjustment is required.
1. Float Switch Check
To check FS, follow the steps below.
1) Turn off the power supply.
2) Remove the front panel, then move the control switch to the "OFF" position. 
3) Remove the base cover, then disconnect one end of the pump tubing to drain the water 
tank. See Fig. 3. After the water tank has drained, reconnect the pump tubing.
4) Remove the control box cover. 
5) Disconnect FS connector from CB 
K5 connector.
6) Check for continuity across FS leads. With 
the water tank empty, FS should be open. 
If open, continue to step 7. If closed, follow 
the steps in "II.E.2. Float Switch Cleaning." 
After cleaning FS, check it again. Replace if 
necessary.
7) Reconnect FS connector to CB K5 
connector, then replace the control box 
cover in its correct position.
8) Move the control switch to the "ICE" position. Replace the front panel in its correct 
position, then turn on the power supply. After 1 min., the 1-min. fill cycle should end and 
the initial harvest cycle should begin. If the initial harvest cycle begins, FS is good and 
the check is complete. If the initial harvest cycle does not begin, continue to step 9.
9) Turn off the power supply.
10) Remove the front panel. Move the control switch to the "OFF" position.
11) Remove the control box cover.
12) Disconnect FS connector from CB K5 connector. 
13) Check for continuity across FS leads. With the water tank full, FS should be closed. 
If FS is closed and the icemaker will not switch from the 1-min. fill cycle to the initial 
harvest cycle, replace CB.
If FS is open, confirm that the water tank is full. If the water tank is not full, check the 
water supply, water filters, and inlet water valve. If the water tank is full, follow the 
steps in "II.E.2. Float Switch Cleaning." After cleaning FS, check it again. Replace if 
necessary.
Legend: 
CB–control board; FS–float switch
Fig. 3
Disconnect This 
End of Pump 
Tubing to Drain 
Water Tank
Base Cover