Hoshizaki MWH KM-515MAH 사용자 설명서

다운로드
페이지 94
83
11. KM-901MAH
70/21
874
396
832
378
785
356
80/27
842
382
778
353
736
334
90/32
832
378
732
332
687
312
lbs./day   kg./day
100/38
826
375
721
327
646
293
70/21
80/27
90/32
watts
100/38
70/21
240
0.91
212
0.80
187
0.71
80/27
219
0.83
175
0.66
158
0.60
90/32
212
0.80
143
0.54
123
0.46
gal./day    m
3
/day
100/38
175
0.66
139
0.52
103
0.39
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
219
15.4
238
16.7
261
18.3
80/27
234
16.4
263
18.5
284
20.0
90/32
238
16.7
284
20.0
306
21.5
PSIG     kg/cm
2
G
100/38
242
17.0
289
20.3
327
23.0
70/21
35
2.5
37
2.6
41
2.9
80/27
36
2.6
39
2.7
44
3.1
90/32
37
2.6
41
2.9
46
3.2
PSIG     kg/cm
2
G
100/38
38
2.7
42
3.0
50
3.5
15,400  BTU/h  [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
20
24
20
21
24
20
22
2.7
4.3
3.3
3.9
3.3
2.8
4.0
19
APPROXIMATE ICE 
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC 
CONSUMPTION
APPROXIMATE WATER 
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP. 
(ºF/ºC)
50/10
70/21
90/32
1631
1632
1675
1710
1715
1600
1625
1632
22
24
26
27
1658
1691
1731
1750
HARVEST CYCLE TIME
HEAD PRESSURE
3.6
3.1
3.9
2.6
2.4
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE
ENG.F-011.1.0205
Note: 
1. Pressure data is recorded at 5 min. into freezing cycle. The data not in bold     
 
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior     
 notice.