[c] SEQUENCE
1st Cycle
1. Unit energized and Control Switch to “ICE”
position. Water supply cycle starts.
position. Water supply cycle starts.
3. Thermistor reads 48°F.
Defrost Timer starts counting.
Defrost Timer starts counting.
2. After 1 minute,
Defrost cycle starts.
Defrost cycle starts.
5. After the first 5 minutes in freeze cycle.
Ready to complete freeze cycle when Float
Switch circuit opens.
Ready to complete freeze cycle when Float
Switch circuit opens.
IMPORTANT
Board never accepts freeze completion signal
within the first 5 minutes in freeze cycle.
within the first 5 minutes in freeze cycle.
IMPORTANT
1. Board never accepts defrost completion signal
within the first 2 minutes in defrost cycle.
within the first 2 minutes in defrost cycle.
2. Defrost cycle time is limited to 20 minutes even if
Defrost Timer does not stop counting.
Defrost Timer does not stop counting.
4. Defrost Timer stops counting.
Defrost cycle is completed and freeze cycle
starts.
Defrost cycle is completed and freeze cycle
starts.
IMPORTANT
Water Valve opening is
limited to 6 minutes.
limited to 6 minutes.