PLEASE READ ENTIRE INSTRUCTION BEFORE PROCEEDING. 
INSTALLATIONS MUST COMPLY WITH ALL LOCAL CODES. 
IMPORTANT:
 Save these Instructions for the Local Electrical Inspector's use. 
INSTALLER:
 Please leave these Installation Instructions with this unit for owner. 
OWNER:
 Please retain these Instructions for future reference 
 
 
IMPROTANT SAFETY INSTRUCTIONS
  
 
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, 
HOODS SHOULD BR INSTALLED WITH VENTILATORS APPROVED FOR USE WITH THE HOOD. 
SEE TABLE   1 OF THIS INSTRUCTION FOR APPROVED VENTILATORS. 
 
WARNING - TO REDUCE THE 
RISK OF FIRE, ELECTRIC 
SHOCK, OR INJURY TO 
PERSONS, OBSERVE THE 
FOLLOWING: 
A. Installation work and Electrical 
Wiring Must be Be Done By Qualified 
Person(s) In Accordance With All 
Applicable Codes & Standards. 
Including Fire-Rated Construction. 
 To Reduce The Risk Of 
Fire, Use Only Metal Duct Work. 
B. Sufficient air is needed for proper 
combustion and exhausting of gases 
through the flue (chimney) of fuel 
burning equipment to prevent 
backdrafting. Follow the heating 
equipment manufactures guideline and 
safety standard such as those published 
by the National Fire Protection 
Association (NFPA) and the American 
Society for Heating, Refrigeration and 
Air Conditioning Engineers 
(ASHRAE), 
and the local code authorities. 
C. When cutting or drilling into wall or 
ceiling, do not damage electrical wiring 
and other hidden utilities. 
D. Before Servicing or Cleaning Unit, 
Switch Power off At Service Panel And 
Lock Service Disconnecting Means to 
Prevent Power From Being Switched On 
Accidentally. When The Service 
Disconnecting Means Cannot be Locked, 
securely Fasten A Prominent Warning 
Device, Such As A Tag, To The Service 
Panel 
 
CAUTION - TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST AIR, BE SURE TO 
DUCT AIR OUTSIDE FOR DUCTED FANS   DO NOT VENT EXHAUST AIR INTO SPACE WITHIN 
WALLS OR CEILING OR INTO ATTICS, CRAWL SPACES OR GARAGES. 
 
 
Read this instruction completely before starting installation. Planning the complete installation before starting any work is 
highly recommended. This includes all aspects of the installation including hood location, ducting, electrical requirements, 
and adequacy of mounting surfaces. 
 
 
 
 
 
 
 
 
 
DUCTING: Use a minimum 8" round duct for VEN030I, VEN060I and VEN060E installations. Use a minimum 10" round 
duct for VEN120E, VEN100E, VEN140E and VEN060I-Dual installations. Use #10100 8" - round transition or #10287 10"-
round transition from hood to ducting. Other Transition options are available   See your Dealer for details. 
 
 
 
 
 
INSTALLATION INSTRUCTIONS 
HOOD MODELS   WSL, WCL, & WER
 
 
TABLE - 1 
Use model VEN030I or VEN060I 
for internal ventilator. Use 
VEN060E, VEN120E, VEN100E 
or VEN140E for remote ventilator
 
This hood has been designed to be used with the ventilators shown in Table-1. 
Before cutting into cabinets, it is necessary to confirm that the correct ventilator 
is being used. Your dealer should have reviewed your needs prior to your 
purchase. Be sure you have the correct ventilation system. 
CAUTION: To Reduce The Risk Of Fire And Electrical Shock, Install This  
Rangehood Only With Blowers Manufactured By Wind Crest.
 
                By CNP INDUSTRIES, INC. 