Viking VIPR162R 사용자 설명서
![Viking](https://files.manualsbrain.com/attachments/e06dbcb7c3f6b371afe2ae78c5a2c3d087abbdf4/common/fit/150/50/806d33188597c2a9e5700d284ff8fd5a13006393d8732de3f703fc413425/brand_logo.png)
7
Downdraft Ventilators
VIKING RANGE, LLC
All Units
*
Must use island trim. Rear countertop trim (supplied with island trim) will be used in this installation.
1. Measure and cut the countertop opening for your width of
cooktop and downdraft.
Cooktop Width & Model
30" VECU
36" VECU
VGSU102
VGSU162
30" VGRT *
36" VGRT *
48" VGRT *
For use with Downdraft Models
VIPR102SS
VIPR162SS VIPR102SS VIPR162SS VIPR102RSS
VIPR162RSS
VIPR182RSS
VIPR102RSS
VIPR162RSS VIPR102RSS VIPR162RSS
Cutout Dimensions
A
28-3/4"
34-3/4"
28-1/16"
34-1/4"
30"
36"
48"
B
20-1/4"
20-1/4" 18-3/4" 18-3/4" 24"
24"
24"
C
27"
33" 27" 33" 27" 33" 45"
D
2-1/4"
2-1/4" 3"
3"
2-3/4" 2-3/4" 2-3/4"
E
7/8"
7/8"
--- --- 1-1/2"
1-1/2"
1-1/2"
F
7/8" 7/8" 1-1/16"
1-1/4" 1-1/2" 1-1/2" 1-1/2"
A
C
B
D
F
E
A
C
B
D
F
Cutout for:
VGSU102 & VGSU162
Cooktops
CUT COUNTERTOP OPENING
Cooktop Width & Model
30" VEC
36" VEC
30" VGC
36" VGC
For use with Downdraft Models VIPR102SS VIPR162SS
VIPR102SS
VIPR162SS
VIPR102RSS
VIPR162RSS
VIPR102RSS
VIPR162RSS
Cutout Dimensions
A
28-7/8"
34-7/8"
27-3/4"
33-3/4"
B
19-1/4"
19-1/4"
18-3/4"
18-3/4"
C
27"
33"
27"
33"
D
2-11/16"
2-11/16"
2-15/16"
2-15/16""
E
15/16"
15/16"
3/8"
3/8"
F
15/16"
15/16"
3/8"
3/8""
Cutout for:
VECU Cooktops &
VGRT Rangetops
A
C
B
D
F
E
A
C
B
D
F
E
Cutout for:
VEC Cooktops
Cutout for:
VGC Cooktops