Vermont Casting DVBR42 사용자 설명서

다운로드
페이지 40
35
DVBR Series Direct Vent Gas Fireplace
20000584
Optional Accessories
Optional Fk-12 Fan Hook-up
1.  Remove control cover from unit.
2.  Remove glass door by rotating latches at bottom 
corners of door. Refer to Page 23.
3.  Remove the 9 screws securing burner to combustion 
bottom.
4.  Remove burner by lifting up and rotating toward front 
of unit.
5.  Set burner aside.
6.  Install FK-12 fan in back of unit between hearth sup-
ports. (Fig. 72)
7.  Secure fan on velcro strips.
8.  Plug fan into EB-1 receptacle.
9.  Be sure fan motor does not touch hearth supports.
Any electrical re-wiring of this fan must be 
completed by a qualified electrician.
Turn off all power before hook-up.
A
A
584-10
Fan placement
DVBR Series
3/11/99   djt
Front of 
Unit
Cold Air Box
Cold Air Box
Base Pan
Base Pan
Hearth Pan
Hearth Pan
Hearth 
Support
Hearth 
Support
See 
Detail
Detail
FK-12 Fan
FK-12 Fan
Access Cover
EB-1 Re-
ceptacle
Fig. 72  FK-12 Fan Kit placement.
584-10
Top View
Side View
Remote Controls
Optional remote control units are available to control 
different functions of the appliance.
 
Model  Functions Controlled
 
RC1 
ON/OFF
 
RC2 
ON/OFF and Temperature
 
IMTFK  Wall mounted thermostat control
Ceramic Refractory Panels
1.  Remove glass and logs.
2.  Insert supports under ceramic hearth panels. 
  (Fig. 73)
3.  Remove three (3) screws securing heat shield to 
combustion dome. (Fig. 74)
4.  Place rear ceramic panel in back of unit. (Fig. 75)
5.  Place side panels.
6.  Replace heat shield, logs and glass.
H101
Ceramic Panel Supports
3/16/99   djt
Burner
Hearth Panel
Ceramic Support
Fig. 73  Ceramic support.
H101
Grate
H103
heat shield
3/1/99   djt
(3) Screws
Heat Shield
Front View
Fig. 74  Heat shield.
H103
Section A
Heat Shield
Side View
Section A