DVBR Series Direct Vent Gas Fireplace
20000584
Clearance to Combustibles
Appliance
 
Top  ......................................................... 0” (0 mm)
 
Bottom ..................................................... 0” (0 mm)
 
Side ......................................................... 0” (0 mm)
 
Back ........................................................ 0” (0 mm)
 
Perpendicular Sidewall ........................... 0” (0 mm)
 
Top of unit to ceiling .......................... 36” (914 mm)
 
Front of unit to combustibles ............. 36” (914 mm)
Venting
Concentric sections of DV Vent ................... 1” (25 mm)
Nonconcentric sections of DV Vent 
 
Sides and bottom .................................  1” (25 mm)
 
Top ........................................................ 2” (51 mm)
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. This 
also applies to the distance between the mantel leg (if 
fitted) and the fireplace.
For the correct mounting height and widths, refer to 
Figures 4a and 4b and the Mantel Chart below.
The distances and reference points are not affected by 
the fitting of a bay window front trim kit.
Noncombustible mantels and legs may be installed at 
any height and width around the appliance. When using 
paint or lacquer, it must be heat resistant to prevent 
discoloration. 
J
F
G
H
I
Mantel
Leg
CFM164a
Mantel Leg Chart
06/22/01   sta
CFM170
DV Builder Front 
View
O
N
M
L
K
CFM164a
Side of 
Combustion Chamber
CFM170
 
 
Mantel Leg 
 
Mantel  Leg from Side 
 
Ref. 
 Depth 
Ref.  of Combusion Opening
 
14”   (356 mm) 
14”  
(356 mm)
 
12”   (305 mm) 
12”  
(305 mm)
 
10”   (254 mm) 
10”  
(254 mm)
 
8”   (203 mm) 
8”  
(203 mm)
 
4”   (102 mm) 
3¹⁄₂”   (89 mm)
Fig. 4b  Combustible mantel minimum installation.
Black 
Surround Face
Mantel Chart
 
 
Mantel 
 
Mantel from Top
 
Ref. 
Shelf Depth 
Ref.  of Comb. Chamber
 
14”   (356 mm) 
18”   (457 mm)
 
12”   (305 mm) 
16”   (406 mm)
 
10”   (254 mm) 
14”   (356 mm)
 
8”   (203 mm) 
12”   (305 mm)
 
1¹⁄₂”   (38 mm) 
8”  
(203 mm)
Fig. 4a Combustible mantel minimum installation.
A B C D E
V
W
X
Y
Z
Fireplace
CFM146
DV Mantel Chart
7/5/01   sta
Bottom of Door Trim
Top of Combustion 
Chamber
CFM146a
Y
E
A
B
C
D
F
Y
B
X
LU584-1
Locating unit
2/4/99   djt
A) Flat on wall  
B) Cross corner 
C)  **Island
D) *Room divider  E) *Flat on wall corner 
F)  Chase installation
Y) 6” minimum
Note (Fig. 1):  
** Island (C) and Room Divider (D) installation is possible as long as 
the horizontal portion of the vent system (X) does not exceed 20’ (610 
cm).  See details in Venting Section.
*  When you install your fireplace in(D) Room divider or (E) Flat on 
wall corner positions (Y), a minimum of 0” (0mm) clearance must be 
maintained from the perpendicular wall and the front of the fireplace.
Fig. 1 Locating Gas Fireplace
LU584-1
Locating Your Fireplace