Vermont Castings DVR28 Direct Vent Gas Fireplace
STEP 1
Locate vent opening on the wall. To locate hole center 
consult with appropriate fireplace dimensions, Page 4. 
Frame as shown below.
Combustible Walls (Fig. 17)Cut a 10³⁄₈”H x 9³⁄₈” W 
(264 x 240 mm) hole through the exterior wall and 
frame as shown. 
Noncombustible Walls (Fig. 17): Hole opening must 
be 7¹⁄₂” (190 mm) in diameter. 
Zero clearance sleeve is only required for 
combustible walls.
STEP 2
Measure wall thickness and cut zero clearance sleeve 
parts to proper length (MAXIMUM 12”/305 mm). Assem-
ble sleeve and attach to firestop with #8 sheet metal 
screws (supplied). (Fig. 18)
STEP 3
Measure the horizontal length requirement for the vent-
ing including a 2” (51 mm) overlap, i.e. from the elbow 
to the outside wall face plus 2” (51 mm). (Fig. 15 or 16)
FP1752 
Zero Clearance Sleeve
2/07
Max. Length 
12” (305mm)
#8 Screws (2)
#8 Screws 
(2)
Adjustable 
Zero Clearance 
Sleeve
#8 Screws 
(2)
Adjustable Zero Clearance Sleeve
ZCS101
Fig. 18  Adjustable zero clearance sleeve.
Firestop
STEP 4
Install the 4” (102 mm) vent to the appliance collar and 
secure with three (3) sheet metal screws. Install the 7” 
(178 mm) vent pipe to the appliance collar and secure 
with three (3) sheet metal screws. It is not necessary 
to seal this connection. If a 45° elbow is being used, 
attach the elbow to the appliance in the same manner 
then attach the venting to the elbow.
It is critical there is no downward slope 
away from the appliance when connecting 
the vent or elbow.
STEP 5
Guide the venting through the vent hole a you place the 
appliance in its installed position. Guide the 4” (102 mm) 
and 7” (178 mm) collar of the vent termination into the 
outer ends of the venting. Do not force the termination. If 
the vent pipes do not align with the termination, remove 
and realign the venting at the appliance flue collars. 
(Fig. 19) Attach the termination to the wall as outlined in 
the instruction sheet supplied with the termination.
FP1751
vent opening
2/07
Vent Opening for Combustible Wall
9³⁄₈”
(240mm)
10³⁄₈”
(264mm)
Fireplace Hearth
Framing 
Detail
Opening for 
Noncombustible Wall
7¹⁄₂”
(190 mm)
FP1751
Fig. 17  Locate vent opening on wall.
Firestop
Top Tabs
Bottom Tabs
Install provided firestop with zero 
clearance sleeve into framing 
opening after drywall or finish 
material is installed. Use the tabs 
for clearance locators top and 
bottom.
FP1005
Side View Vent Termination
1/25/00   djt
Finished Wall
Vent 
Termination
FP1753
Fig. 19  Side view of final unit location.
Firestop
Zero Clearance 
Sleeve
Rear Wall Installation
Twist Lock Pipe