DVBR Series Direct Vent Gas Fireplace
20000584
V584-201
Horizontal Run
2/99   djt
10’ 
(254cm)
7’
(178cm)
8’
(244cm)
A
B
A + B = 17’ Max.
V584-201
Fig. 29  Maximum vent run with elbows.
In Figure 28 & 29, dimension A plus B must not be 
greater than 17’ (5.2m)
• 
The maximum number of 45° elbows permitted per 
side wall installation is two (2). These elbows can be 
installed in either the vertical or horizontal run.
• 
For each 45° elbow installed in the horizontal run, 
the length of the horizontal run MUST be reduced by 
18” (457mm). This does not apply if the 45° elbows 
are installed on the vertical part of the vent system.
• 
The maximum number of elbow degrees in a system 
is 270°. (Fig. 30)
Example:
   
Elbow 1 
90°
   
Elbow 2 
45°
   
Elbow 3 
45°
   
Elbow 4 
90°
  Total angular variation  = 
270°
1
2
3
4
1
2
3
4
1 + 2 + 3 + 4 = 270°
FP1180
Fig. 30   Maximum elbow usage.
3 x 90° 
Elbows
3 x 90° 
Elbows
FP1176
Fig. 26  Maximum three (3) 90° elbows per installation.
Max 20"
Max 20"
36" 
(914mm) 
Max.
36" 
(914mm) 
Max.
FP1177
Fig. 27  Maximum horizontal runwith no rise.
7'6"
A
B
90o
A + B = 17' (Max.)
FP1178
Fig. 28  Horizontal run reduction.
• 
If a 90° elbow is used in the horizontal vent run 
(level height maintained) the horizontal vent  length 
is reduced by 36” (914mm). (Fig. 28, 29) This does 
not apply if the 90° elbows are used to increase or 
redirect a vertical rise. (Fig. 26)
Example: According to the vent graph (Page 15) the 
maximum horizontal vent length in a system with a 
7¹⁄₂” (191mm) rise is 20” (508mm) and if a 90° elbow is 
required in the horizontal vent it must be reduced to 17’ 
(5.2m).