페이지 31
3
360DVS Series Direct Vent Fireplaces
10006326
This gas appliance should be installed by a qualified installer in 
accordance with local building codes and current CSA-B149.1 
Installation Codes for Gas Burning Appliances and Equipment. 
If the unit is being installed in a mobile home, the installation should 
comply with the current CAN/CSA Z 240.4 code. For U.S.A. Instal-
lations, follow local codes and/or the current National Fuel Gas 
Code, ANSI Z223.1/NFPA 54.
In the Commonwealth of Massachusetts, all gas fittings 
and installation of this appliance shall be done by a 
licensed gas fitter or licensed plumber.
FOR SAFE INSTALLATION AND OPERATION PLEASE 
NOTE THE FOLLOWING:
1.  This fireplace gives off high temperatures and should be 
located out of high traffic areas and away from furniture and 
draperies.
2.  Children and adults should be alerted to the hazards of 
high surface temperatures of this fireplace and should stay 
away to avoid burns or ignition of clothing.
3.  CAUTION: Due to high glass surface temperature, chil-
dren should be carefully supervised when in the same 
room as fireplace.
4.  Under no circumstances should this fireplace be modified. 
Parts removed for servicing should be replaced prior to 
operating this fireplace again.
5.  Installation and any repairs to this fireplace must be per-
formed by a qualified installer, service agency or gas sup-
plier. A professional service person should be contacted to 
inspect this fireplace annually. Make  it a practice to have 
all of your gas fireplaces checked annually. More frequent 
cleaning may be required due to excess lint and dust from 
carpeting, bedding material, etc.
6.  Control compartments, burners and air passages in this 
fireplace should be kept clean and free of dust and lint. 
Make sure the gas valve and pilot light are turned off be-
fore you attempt to clean this fireplace.
7.  The venting system (chimney) of this fireplace should be 
checked at least once a year, and if needed, your venting 
system should be cleaned.
8.  Keep the area around your fireplace clear of combustible 
materials, gasoline and other flammable vapor and liquids. 
This fireplace should not be used as a drying rack for 
clothing, nor should Christmas stockings or decorations be 
hung on or around the fireplace.
9.  Under no circumstances should any solid fuels (wood, coal, 
paper or cardboard, etc.) be used in this fireplace.
10. The flow of combustion and ventilation air must not be 
obstructed in any way.
11. When the fireplace is installed directly on carpeting, vinyl 
tile, or any combustible material other than wood, it must 
be installed on a metal or wood panel extending the full 
width and depth of the fireplace.
12. This fireplace requires adequate ventilation and combus-
tion air to operate properly. 
13. This fireplace must not be connected to a chimney flue serving 
a separate solid fuel-burning fireplace.
14. When the fireplace is not in use, it is recommended the 
gas valve be left in the “OFF” position. 
Installation & Operating Instructions
This appliance may be installed in an aftermarket, per-
manently located, manufactured home, or mobile home 
where not prohibited by local codes.
This appliance is only for use with type of gas  
indicated on the rating plate. This appliance is not 
convertible for use with other gases, unless a certified 
kit is used.
Proposition 65 Warning: Fuels used in gas, wood-
burning or oil fired appliances, and the products of 
combustion of such fuels, contain chemicals known 
to the State of California to cause cancer, birth de-
fects and other reproductive harm.
California Health & Safety Code Sec. 25249.6
IMPORTANT:
PLEASE REVIEW THE FOLLOWING CAREFULLY
Remove any plastic from trim parts before turning the 
fireplace ON.
It is normal for fireplaces fabricated of steel to give off 
some expansion and/or contraction noises during the 
start up or cool down cycle. Similar noises are found 
with your furnace heat exchanger or car engine.
It is not unusual for your gas fireplace to give off some 
odor the first time it is burned. This is due to the curing of 
the paint and any undetected oil from the manufacturing 
process. 
Please  ensure  that  your  room  is  well  ventilated 
- open all windows.
It  is  recommended  that  you  burn  your    fireplace  for 
at least ten (10) hours the first time you use it. If the 
optional fan kit has been installed, place the fan switch 
in the “OFF” position during this time.
 
A  Wall Location (Fig. 1)
 
  Y  (Minimum distance between a glass panel and a 
 
 parallel wall)  =  3’ (914mm)
 
  Z  (Minimum distance between edge of a glass panel    
 and an adjacent wall)  =  3” (76mm)
  B  Island Location (Fig. 1)
 
  X  (Maximum length of horizontal venting)  =  20’ (6.1m)     
   Refer to the venting section in this manual for specific dimen-
sions.
Fig. 1  Locating your gas fireplace
Locating Your Fireplace
X
X
X
Y
Y
Y
Z
A
A
B
LU584-2
360DVS
locate fireplace
LU584-2