7
10005360
LHE Series Natural Vent Insert
FP297
INSTA VENT FREE
R MODEL GAS SUPPLY 
8/24/96
1/2" Gas Supply
1/2" x 3/8" Shut Off Valve
3/8" Nipple
3/8" Union
FP297
Fig. 4  Typical gas supply installation.
3/8" Nip-
ple
Gas Supply Pressures
This heater must be isolated from the gas supply piping 
system by closing its individual manual shut-off valve 
during any pressure equal to or less than 1/2 psig 
(3.45kPa).
The heater and its individual shut-off valve must be 
disconnected from the gas supply piping system during 
any pressure testing of that system at test pressures in 
excess of 1/2 psig (3.45kPa).
Fan Kit
115 volt, 60 Hz. 56w (Model FK24)
NOTE: The LHER20 and LHER30 are not designed for 
a fan kit.
The fan kit  includes the following:  fan, temperature 
sensor, speed control and a 6 ft. cord.  The following 
explains how to start and set the fan for automatic 
operation.
1.  Plug in the electrical cord.
2.  Start gas fire - see lighting procedures.
3.  Turn on fan speed control.
4.  Wait until the unit has warmed up sufficiently to 
activate the temperature sensor, approx. 5-10 
minutes.
5.  Once fan starts, adjust speed control to desired fan 
speed. The fan will now automatically come on every 
time the fireplace is in operation. Should the fan not 
be needed simply turn off the speed control.
The appliance, when installed must be 
electrically connected and grounded in 
accordance with local codes or, in the ab-
sence of local codes, with the current CSA 
C22.1 Canadian Electrical Code.
U.S. Installations,
 follow local codes and the 
National Electrical Code, ANSI/NFPA No. 70.
Should this fan require servicing, the 
power supply must be disconnected.  For 
rewiring  of any replacement components 
refer to Figure 6.
Fan Removal Instructions
1.  Turn off gas and electricity.
2.  Remove the front glass.
3.  Remove the logs.
CAUTION: Logs may be hot!
4.  For Model LHEC20: remove burner assembly and 
bracket rear log. For Model LHEC30: remove brack-
et rear log and cover fan.
5.  Remove the fan mounting nuts (2 nuts). (Fig. 5)
6.  Slip off the electrical connector at the motor.
7.  Lift out the fan.
8.  To reinstall reverse procedure.
FP1252
FK24 install
1/03
Thermal Sensor is 
Attached to Burner 
Base
Fan is Installed 
at the Back of the 
Air Intake Box
Fan Speed Control/Junction Box
Screw 
Stud
Screw Stud
FP1252
Fig. 5  Fan location.
FP394
WIRING DIAGRAM
11/20/96
Fan
Temperature Sensor
Speed 
Control
Black
White
Ground
FP394
Fig. 6  Wiring diagram RN/RP. NOTE:  For comfort valve wir-
ing diagram refer to Page 18, Figure 27.
Installation of Trim Switch 
for RN/RP Gas Valves
1.  Thread wire through openings on the right side of fire-
place.  Do not cut wire or insulation on metal edges. 
2.  Insert  ON/OFF  switch  with  wiring  assembly  into  the 
bracket switch with the pre-punched opening mounted 
on the right side of the trim. (Fig. 7)
3.  For left side installation, relocate the bracket switch 
to the left side of the trim kit and repeat Step 2. (Fig. 
8)
4.  Connect wiring from the switch to the gas valve (Fig. 
9a & b).