Vermont Casting DVRSL 사용자 설명서

다운로드
페이지 35
- 30 -
4.
Push in gas control knob slightly
and turn clockwise
     to
"OFF".  Do not force.
5.
Close control access panel.
C.
Use only your hand to push in or turn the gas control
knob.  Never use tools.  If the knob will not push in or turn
by hand, do not try to repair it, call a qualified service
technician.  Force or attempted repair may result in a fire
or explosion.
D.
Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect
the fireplace and to replace any part of the control system
and any gas control which has been under water.
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING:
If you do not follow these instructions exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
A.
This fireplace has a pilot which must be lit manually.
When lighting the pilot follow these instructions exactly.
B.
BEFORE LIGHTING smell all around the fireplace area for
gas.  Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any fireplace.
Do not touch any electric switch
Do not use any phone in your building
Immediately call your gas supplier from a neighbor's
phone.  Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the Fire
Department
TO TURN OFF GAS TO FIREPLACE
LIGHTING INSTRUCTIONS
LIGHTING AND OPERATING INSTRUCTIONS
1.
Turn the On/Off switch to Off position or set the
thermostat to lowest setting.
2.
Turn off all electric power to the  fireplace if
service is to be performed.
3.
Open control access panel.
it
PILOT
OF
F
O
N
FOR FIREPLACES EQUIPPED WITH SIT 820 MILLIVOLT GAS VALVE
8.
Visibly locate pilot by main burner.
9.
Turn knob on gas control counterclockwise
 to "PILOT".
10. Push in control knob all the way and hold in.
Immediately light the pilot by repeatedly depressing
the piezo spark ignitor until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit.  Release knob and it
will pop back up.  Pilot should remain lit.  If it goes
out, repeat steps 5 through 8.
• If knob does not pop up when released, stop and
immediately call your service technician or gas
supplier.
• If the pilot will not stay lit after several tries, turn
the gas control knob to "OFF" and call your service
technician or gas supplier.
11.  Turn gas control counterclockwise                    to
"ON" position.
12. Replace glass door.
13. Turn on all electric power to the fireplace.
14. Turn the On/Off switch to On position or  set
thermostat to desired setting.
15. This valve is equipped with a Hi/Lo feature.  Set
fireplace input as desired.
1.
STOP!  Read the safety information above on this
label
2.
Turn the On/Off switch to Off position or set the
thermostat to lowest setting.
3.
Turn off all electric power to the fireplace.
4.
Open control access panel.
5.
Remove glass door before lighting pilot.  (See Glass
Door Removal).
6.
Push in gas control knob slightly and turn clockwise
to                    "OFF".
7.
Wait fifteen (15) minutes to clear out any gas.  Then
smell for gas, including near the floor.  If you smell
gas, STOP!  Follow "B" in the safety information
above on this label.  If you don't smell gas, go to
the next step.