Vermont Casting DVRSL 사용자 설명서

다운로드
페이지 35
- 8 -
,,
,,
,
,
Outside Corner
Inside Corner
Termination Clearances
Termination clearances for buildings with combustible and noncombustible exteriors. 
A =
Combustible 
  6"(152mm)
Noncombustible 
  2"(50mm)
B =
Combustible 
  6"(152mm)
Noncombustible 
  2"(50mm)
,
A
,,
,,
Balcony - 
with no side wall
G = 
Combustible
  24"(610mm)
Non-Combustible
  18"(457mm)
  
G
Balcony - 
with perpendicular side wall
H = 24"(610mm)
J = 20"(508mm)
      
H
J
B
Recessed Location
C = Maximum depth of 48"
       (1219mm) for recessed 
       location.
       
D = Minimum width for back wall 
       of a recessed location.
       Combustible 38"(965mm)
       Noncombustible 24"(610mm)
E = Clearance from corner in 
       recessed location.
       Combustible 6"(152mm)
       Noncombustible 2"(50mm)
,,
C
D
C
E
V
V
Combustible &
Non-Combustible
V
V
V
Fig. 8