LDVR Series Direct Vent Gas Fireplace
10007317
Noncombustible materials such as brick or tile may be 
extended over the edges of the face of the fireplace. 
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the 
brick or tile will have to be installed flush with the edges 
of the fireplace.
Final Finishing
33LDVR / 36LDVR / 39LDVR / 43LDVR
Certified To
ANSI Z21.88-2005 / CSA  2.33-2005
Vented Gas Fireplace Heaters
Framing and Finishing 
  Inlet Minimum 
5.5” w.c. 
11.0” w.c.
  Inlet Maximum 
14.0” w.c. 
14.0” w.c.
  Manifold Pressure 
3.5” w.c. 
10.0” w.c.
Gas Inlet and Manifold Pressures
 
Natural 
LP (Propane)
Check fireplace to make sure it is levelled 
and properly positioned.
To mount the appliance:
1.  Choose the location.
2.  This unit comes with four (4) flanges pre-mounted 
on both sides of the fireplace to allow two different 
drywall thicknesses to be used. Flange “A” is for 1/2” 
drywall while flange “B” is for 5/8” drywall.
3.  Bend the desired flanges out 90° on both sides of 
the fireplace. Slide the fireplace into the framed 
opening until the flanges contact the front surfaces 
of the framing. Level the unit and secure it firmly in  
place.
FP1544
nail flange
1/05
Fig. 4  Nailing flanges.
 
Flange 
Drywall
  Position 
Depth
 
1/2” / 13 mm
 
5/8” / 16 mm
Flange Location for 
Desired Drywall Depth
FP1539
A
B
33LDVR units: GFRN2I0, GFRL2I0, GFRE2I0
36LDVR units: GFRN2J0, GFRL2J0, GFRE2J0
39LDVR units: GFRN2K0, GFRE2K0
43LDVR units: GFRN2N0, GFRE2N0
*Using conversion kit
    
 
 
Max. 
Min. 
Air
    
 
Gas 
Input 
Input 
Shutter
  Model 
Fuel  Control  BTU/h  BTU/h 
Adj.
  33LDVRRN 
Nat  Millivolt  16,000  11,200 
3/16”  
    
 
 
 
 
Open
  33LDVRRP  Prop  Millivolt  16,000  12,000  Fully Open
  33LDVREN 
Nat 
24V  
16,000  11,200 
3/16” 
    
 
Hi/Lo 
 
 
Open
  33LDVREP  Prop* 
24V 
16,000  12,000  Fully Open 
    
 
Hi/Lo
  36LDVRRN 
Nat  Millivolt  19,500  13,650 
Top &  
    
 
 
 
 
Bottom 
    
 
 
 
 
Hole Half 
    
 
 
 
 
Closed
  36LDVRRP  Prop  Millivolt  19,500  14,625  Fully Open
  36LDVREN 
Nat 
24V 
19,500  13,650 
Top &  
    
 
Hi/Lo 
 
 
Bottom 
    
 
 
 
 
Hole Half 
    
 
 
 
 
Closed
  36LDVREP  Prop* 
24V 
19,500  14,625  Fully Open 
    
 
Hi/Lo
  39LDVRRN 
Nat  Millivolt  23,000  16,100 
Top &  
    
 
 
 
 
Bottom 
    
 
 
 
 
Hole Half 
    
 
 
 
 
Closed
  39LDVRRP  Prop*  Millivolt  22,500  16,875  Fully Open
  39LDVREN 
Nat 
24V 
23,000  16,100 
Top &  
    
 
Hi/Lo 
 
 
Bottom 
    
 
 
 
 
Hole Half 
    
 
 
 
 
Closed
  39LDVREP  Prop* 
24V 
22,500  16,875  Fully Open
  43LDVRRN 
Nat  Millivolt  26,000  18,200 
Top &  
    
 
 
 
 
Bottom 
    
 
 
 
 
Hole Half 
    
 
 
 
 
Closed
  43LDVRRP  Prop*  Millivolt  24,000  18,000  Fully Open
  43LDVREN 
Nat 
24V 
26,000  18,200 
Top &  
    
 
Hi/Lo 
 
 
Bottom 
    
 
 
 
 
Hole Half 
    
 
 
 
 
Closed
  43LDVREP  Prop* 
24V 
24,000  18,000  Fully Open 
    
 
Hi/Lo 
Gas Specifications