Flexible aluminium pipes, corrosion-protected
sheet metal pipes and exhaust air pipes whose
material conforms to fire B1 in accordance with 
DIN 4102 can be used. Exhaust air pipes should 
have a nominal diameter of 6 ´ ´ / 150 mm.
Pay particular attention to ensuring that
– the exhaust air ducts and pipes are kept as short
as possible
– the pipes are not laid at an acute angle, but as
bends and that they are inserted into the shaft at
an inclined upward angle and
– there are no cross-sectional constrictions in the
upward direction (this reduces the volume flow).
As standard, the blow-out opening of the extractor
hood is in the upward direction.
To pass exhaust air through the outer wall, we 
recommend the use of our telescopic wall box 
TM 150-045 (Ø 6 ´ ´ / 150 mm).
Note:
to prevent the ingress of water, e.g. condensate or
rain water from an uncovered exhaust air shaft, our
condensate separator RV 060-150 must be installed
in the exhaust air line. The condensate separator
must still be accessible after installation.
The duct units listed below are available depen-
ding on the height of the ceiling:
Stainless steel-design ventilation duct:
LK 590-010 
for ceiling heights of 
7 ´´ 10 ´ ´ - 8 ´´ 8 ´ ´ / 2.39 - 2.64 m
LK 590-020 
for ceiling heights of 
8 ´´ 8 ´ ´ - 9 ´´ 6 ´ ´ / 2.64 - 2.89 m
LK 590-030 
for ceiling heights of 
9 ´´ 6 ´ ´ - 10 ´´ 4 ´ ´ / 2.89 - 3.14 m
Aluminium-design ventilation duct:
LK 590-011 
for ceiling heights of 
7 ´´ 10 ´ ´ - 8 ´´ 8 ´ ´ / 2.39 - 2.64 m
LK 590-021 
for ceiling heights of 
8 ´´ 8 ´ ´ - 9 ´´ 6 ´ ´ / 2.64 - 2.89 m
LK 590-031 
for ceiling heights of 
9 ´´ 6 ´ ´ - 10 ´´ 4 ´ ´ / 2.89 - 3.14 m
The dimensions above refer to a distance of 5’3” /
1.60 m from the floor to the bottom edge of the
hood.
If required, custom made duct units are available at
an extra charge.
The power connection must be placed within the
ventilation duct on the ceiling.
(15 
15
/
16
") 405
(47 
3
/
16
") 1200
(27") 700
(9 
14
/
16
") 251,5
Fig. 18
2.39 - 3.14 m
7’10” - 10’4”
ceiling height
min. 600 (24
´´ ´´
) over electric hob
min. 762 (30
´´ ´´
) over gas hob