JAI CV-M4+ 사용자 설명서

다운로드
페이지 31
CV-M4
+
/M4
+
CL, CV-M7
+
/M7
+
CL
 
 
- 19 - 
 
 
6.7. Frame-delay read out Mode 
In this mode the pre selected exposure starts from the leading edge of the trigger pulse, H 
synchronous or H a-synchronous. It can be the 10 steps in normal or 1056 steps in programmable. 
SM=0 or SM=1. The resulting video is read out at the trailing edge of the trigger. 
This mode will operate with full and partial scanning and with V binning (M4
+
 and M4
+
CL only). 
Partial scanning and binning in combinations is not allowed. 
If smearless read out (SL=1) is used, the exposure starts with a delay 133H (5.23 msec.) after the 
trigger. An EEN pulse will indicate the active accumulation time, and a FEN pulse indicates that 
the resulting video is read out. 
 
To use this mode:  
Set function: 
Trigger mode “Frame delay read out”  
TR = 3 
 
“H synchronous accumulation” 
HC=0, HC=1 
 “Smearless 
readout” 
SL=0, 
SL=1 
 
 
Polarity and other functions 
Input: 
Ext. trigger to LVDS/Camera Link or pin 10 on 12-pin connector.  
 
 
 
Important notes on using this mode.
 
•  The duration of the trigger should be longer than the exposure time + (>2H to <3V.) 
(>72.64µsec to <120msec). 
•  The minimum trigger interval should be >(trigger pulse width + 1 frame). A new trigger 
must not be applied during the previous frame read out. (Before FEN is high). 
 
 
 
 
 
Fig. 23 Frame Delay