HR150 AND HR200 Perfect Window™ FRESH AIR VENTILATION SYSTEMS
69-0994—4
4
3. Condensate Tray and Drain
Condensation normally forms on the heat exchange core during the cold 
weather (below 29°F or -2°C). Moisture can build up when the warm air from 
your home comes in contact with the cold air from outside. The tray collects the 
moisture and funnels it to the drain. The drain pans are made of therrnoformed 
plastic for easy cleaning.
4. Defrost Mechanism
The built-in defrost mechanism will remove frost which can accumulate in colder 
weather (21°F [-6°C] and colder). The type of defrost mechanism used is known 
as “damper style”. This consists of an electronically controlled damper door 
(attached to a small electric motor) that moves to block off the outside cold air 
entering the ventilator. If the outside temperature drops below 27°F (-3°C), the 
defrost timer is activated. The timer activates the motor driven damper door 
mechanism which temporarily moves to close off the outdoor air supply and 
opens another port on the ventilator that allows warm indoor air to enter the core 
to help the defrost. Approximately three minutes after the defrost cycle is acti-
vated, the timer will signal the damper to return to its original position for a 
2.7 minute period. The defrost cycle will repeat until the outside temperature 
rises above 27°F (-3°C).
5. Thermally Conductive Core
The cross flow heat recovery core transfers heat between the two airstreams. 
The core removes easily for cleaning or service.
6. Controls - Speed Control
Easy operation, simply rotate the Perfect Window™ ventilator fan speed control 
to your desired setting.
DAMPER DEFROST
(MOTOR AND DOOR)
CORE INSTRUCTIONS
CABINET
DEFROST PORT (NON-DUCTED)
FILTER CLIPS (2)
HEAT EXCHANGE CORE
FILTERS (2)
H CHANNEL
(CORE GUIDE) (4)
DRAIN P TRAP
DUCTING 
(4 PORTS)
SQUIRREL 
CAGE FAN
MAIN MOTOR
DRAIN PANS
DRAIN LINE
DOOR KEEPER PLATE (2)
INSULATED 
ACCESS DOOR
M11705A