For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
Listed by 
Underwriters 
Laboratories
Specification Created 6/08
110215
69-5/8"
35-7/8"
Depth Including Handles
29-1/2" - Tubular Handles
30-1/4" - Professional Handles
27-1/2"
Depth
35-7/8"
Case Width
The Installation Space
Electrical 
A 115V, 60Hz., 15 or 20 amp power supply is required. An 
individual properly grounded branch circuit or circuit breaker 
is recommended. Install a properly grounded 3-prong 
electrical receptacle recessed into the back wall. Electrical 
must be located on rear wall as shown.
 
Note: GFI (ground fault interrupter) is not recommended.
Water Line 
The water line can enter the opening through the floor 
or back wall. Route GE SmartConnect
 Kit or 1/4" O.D. 
copper tubing between the cold water line and the water 
connection location at the front of the refrigerator. The 
tubing must be long enough to extend to the front of the 
refrigerator. The installation of an easily accessible shut-off 
valve in the water line is required.
Door Swing Clearances
The installation must allow for clearances to adjacent walls 
or cabinets.
Dimensions and Installation Information (in Inches)
ZFGP21HXSS 
GE Monogram
®
 20.6 Cu. Ft. French Door Two Drawer  
Freestanding Refrigerator