Electrolux 318201761E30GF74GPS 사용자 설명서

다운로드
페이지 30
10
Preparing for Installation
CABINET AND COUNTERTOP PREPARATION
NO
NO
NO
NO
NOTES
TES
TES
TES
TES
If cabinet storage space is to be provided directly above the range, the risk of
personal injury may be reduced by installing a ventilating hood that projects
horizontally a minimum of 5 inches beyond the face of the cabinets.
The range may be installed flush to the rear wall. We recommend installing a
noncombustible material on the rear wall above the range and up to the vent
hood. It is not necessary to install noncombustible materials behind the range
below the countertop height.
The minimum distance from the sides of the range above the countertop to
combustible side walls must be at least 10 inches..
All models are delivered with a 3.5” backguard from the factory. A  9” backguard
is available on the E36GF75GPS AND E36GF76GPS as options.
Utilities may be located: In the lower left corner of the adjacent right cabinet.
(Refer to Figure 2)
IMPOR
IMPOR
IMPOR
IMPOR
IMPORT
T
T
T
TANT
ANT
ANT
ANT
ANT
Contact your local building department to verify compliance with local code
interpretation.
Check your local building codes for the proper method of installation. In the
absence of  local codes, this appliance should be installed in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54. In Canada, installation must
conform to current Natural Gas Installation Code, CAN1-1.1-M and the local codes
where applicable. This range has been design-certified according to ANSI Z21.1b,
latest edition. Be certain that the appliance being installed is correct for the gas
service being provided. Refer to the rating label located on the kick panel and/or the
table on page 7 for gas supply requirements.
All dimensions shown are based on standard American cabinets, 36 inches
(914mm) high at the finished countertop by 24 inches (610mm) deep, with a 25
inch (635mm) overall countertop depth. When installing the range into nonstandard
cabinets, minimum clearances shown in the diagrams on page 11 must be
maintained.
Carefully check the location where the range is to be installed. For best
performance, the range should be placed away from drafts that may be caused by
doors, windows and HVAC outlets.