111
Reference Documents 
Maintenance Error Codes
Technical Addendum
Error
Code
Description
Action
0001 
TIMEOUT COLD START:
System programming OK.
No action required; however, if 
problem persists, troubleshoot 
the processor.
0002 
POWER UP WARM START:
System programming OK. 
No action required; however, if 
problem persists, troubleshoot 
the processor.
0003 
SOFTWARE COLD START:
System programming OK. 
If problem persists, troubleshoot 
the processor.
0004 
SOFTWARE WARM START:
System programming OK. 
If problem persists, troubleshoot 
the processor.
0005 
Reset - DIAGNOSTIC 
SWITCH:
 
0006 
INCOMPLETE COLD START:
System cold-started while
restart in progress. 
If problem persists, troubleshoot 
the processor.
0007 
SANITY TIMEOUT RESET:
Faulty software, module, carrier, 
or processor sanity timer. 
Check module and/or 
processor.
0008 
MAX RESET COUNT 
EXCEEDED:
System cold-started because of 
too many warm starts. 
If problem persists, troubleshoot 
the processor.
0009 
FRIGID START:
System restarted and initialized to 
defaults; also logged after System 
Erase. 
If processor was removed while 
in use, system may perform 
frigid start because of loss of 
system programming. Restore 
system as described in 
System 
Programming and Maintenance 
(SPM).
000A 
POWER UP COLD START:
RAM failure in processor; system 
programming OK. 
If problem persists, check 
processor.
000B 
CARD
INSERTED/REMOVED: 
None.
000C 
SLOT STREAM CNT 
EXCEEDED:
Slot generated excessive 
interrupts. 
If problem persists, check 
module.
000D 
FMWR NOT IN STANDBY 
MODE:
Module firmware not in standby 
mode. 
If problem persists, check 
module.
000E 
COMMAND BUFFER FULL: 
If problem persists, check 
processor and module.
000F 
T
ASK RUNNING TOO LONG 
None; if problem persists, check 
processor.