Mitsubishi Electronics FR-A701 사용자 설명서

다운로드
페이지 259
20/28
BCN-C22005-675
3
Extended parameter setting ranges (Pr. 263, Pr. 505, Pr. 885)
(1) Power failure-time deceleration-to-stop function
(2) Speed display and speed setting
(3) Regeneration avoidance function
The setting ranges of the following parameters have been extended. 
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
263
Subtraction starting 
frequency
60 Hz
 0 to 400 Hz
When output frequency ≥ Pr. 263
Decelerate from the speed obtained from output 
frequency minus Pr. 262.
When output frequency < Pr. 263
Decelerate from output frequency
9999
Decelerate from the speed obtained from output 
frequency minus Pr. 262.
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
505
Speed setting 
reference
60 Hz
 1 to 400 Hz Set the reference speed for Pr. 37.
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
885
Regeneration 
avoidance 
compensation 
frequency limit value
6 Hz
 0 to 30 Hz
Set the limit value of frequency which rises at 
activation of regeneration avoidance function.
9999
Frequency limit invalid
bcnc22005635.fm  20 ページ  2014年12月11日 木曜日 午後5時59分