Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Translations and Testing 
110
Miscellaneous Translations 
Attendant Backup (Switch)
Use the change console-parameters command to administer the Attendant 
Backup parameters. In addition, you must assign a 
 button to the 
backup telephones. See 
 for more information.
On Page 1, administer the following:
Calls in Queue Warning
 — This level should be set to 1 if the 
customer uses the backup telephones for most call handling. If the 
customer uses the attendant console for most call handling, you can set 
this level to a higher threshold. The customer may have to experiment with 
this setting to find a good working queue level.
Ext Alert Port (TAAS)
 — This field must have an analog circuit 
equipment location administered even if you do not have external ringing 
equipment connected to the circuit. This is required to allow the Attendant 
Backup feature to work properly.
Backup Alerting
 — Enter y. If Tenant Partitioning is enabled on the 
switch, the Backup Alerting option cannot be used.
Queue Calls
change console-parameters                               
Page   1 of 
4
                              CONSOLE PARAMETERS
         Attendant Group Name: OPERATOR
                          COS: 1                                  COR: 1
       Calls in Queue Warning: 1                    Attendant Lockout? y
        Ext Alert Port (TAAS): 01A1216
CAS: none
                                              Night Service Act. Ext.: 
IAS (Branch)? n
IAS Tie Trunk Group No.:
IAS Att. access Code:
Alternate FRL Station:
Backup Alerting? y
DID-LDN Only to LDN Night Ext? n
Attendant Vectoring VDN: