Translations and Testing 
158
Switch-to-INTUITY Translations 
TCP/IP Signaling
The TCP/IP signaling link requires administration on both the switch and the 
INTUITY. Any switch type (csi, si or r) can use a TCP/IP link. The TCP/IP link 
supports the PMS Interface for GuestWorks (see 
). This section includes 
procedures for testing the link.
TCP/IP Link (Switch)
On the switch, you must do the following to administer the TCP/IP link:
1.
Assign the bus bridge (
csi systems only)
2.
Assign node names
3.
Assign IP interfaces
4.
Assign an ethernet data module
5.
Assign a processor interface channel
6.
Assign IP routes (if needed).
Assign the Bus Bridge (csi Systems Only)
Using the change system-parameters maintenance command, Page 2, verify 
that the Bus Bridge Packet Interface 2 has been enabled for the C-LAN circuit 
pack. If it is not already assigned, enter the C-LAN circuit pack equipment 
location, and use the defaults for the Timeslot Port fields as shown below.
change system-parameter maintenance
Page 2 of 4
MAINTENANCE-RELATED SYSTEM PARAMETERS
MINIMUM MAINTENANCE THRESHOLDS ( Before Notification )
TTRs: 4 
CPTRs: 1 
Call Classifier Ports:
MMIs: 0 
VCs:
TERMINATING TRUNK TRANSMISSION TEST (Extension)
Test Type 100: 
Test Type 102: 
Test Type 105:
ISDN MAINTENANCE
ISDN-PRI TEST CALL Extension: 
 ISDN BRI Service SPID: 
DS1 MAINTENANCE
DSO Loop-Around Test Call Extension: 
LOSS PLAN (Leave Blank if no Extra Loss is Required)
Minimum Number of Parties in a Conference Before Adding Extra Loss: 
SPE OPTIONAL BOARDS
Packet Intf1? y 
Packet Intf2? y 
Bus Bridge: 03C05
Inter-Board Link Timeslots
Pt0: 6
Pt1: 1
Pt2: 1