Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Translations and Testing 
174
Switch-to-INTUITY Translations 
X.25 Signaling
The X.25 PI link requires administration on both the switch and the INTUITY. Only 
the 
si and r systems can use an X.25 link. A csi system must use TCP/IP or Mode 
Code Integration. This section includes procedures for testing the link.
X.25 Link (Switch)
Use the following procedures to administer the link between the switch and the 
INTUITY for administrative voice messaging. This administration is applicable for 
si or r systems using a direct IDI connection.
Data Modules on an si System
Use the add data-module command on an 
si system to administer the data 
module parameters for a processor interface (PI) link. For this connection, the 
data modules are integrated into the TN765 PI circuit pack. Set the options as 
shown, except use the correct extension, COS, and COR as set up for your 
installation.
You must set the
 Enable Link 
field to n at this time. After you have set up the 
processor interface channel, you must go back and enable the link. 
add data-module 7991
Page
1
of
1
DATA MODULE
Data Extension: 7991
Name: intuity
Type: procr-infc
COS: 15
Maintenance Extension: 7995
Physical Channel: 01
COR: 50
Destination Number: eia
ITC: restricted 
TN: 
Establish Connection? y
Link: 1
DTE/DCE: DTE
Connected Data Module: DCE
Enable Link? n
Clocking: internal
ABBREVIATED DIALING
List1:
SPECIAL DIALING OPTION: 
ASSIGNED MEMBERS (Station with a data extension button for this data module)
Ext
Name
1: