Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Translations and Testing 
201
INTUITY Lodging-to-PMS Translations 
Testing the INTUITY Lodging-to-PMS Link
After the connection is complete, and the link is active, the mini-tester should 
show the following results (see the Note on 
). The leads marked with an 
asterisk are controlled by the INTUITY system, and the PMS controls the other 
leads.
!
CAUTION:
After using a mini-tester to check data leads, you MUST remove the 
mini-tester from the connection. DO NOT leave the mini-tester in-line during 
actual operation.
After the connection is complete and the INTUITY link is active, the following may 
indicate that the PMS is not active. Check with the vendor to verify whether the 
link is active.
TD*
RTS*
DTR*
RD
CTS
DSR
CD
green
green
red
green
red
dark
green
TD*
RTS*
DTR*
RD
CTS
DSR
CD
red
red
red
red
red
dark
green