208
Switch-to-PMS Link Translations
Switch-to-PMS Link Translations
Administration of the switch-to-PMS link includes the following:
■
Hospitality parameters (
)
■
DCP link using the network control (netcon) data module for
si system
) and a processor data module on all systems (
)
■
Housekeeping status feature access codes and definitions (
■
Controlled restrictions (
).
Hospitality Parameters
Use the change system-parameters hospitality command to administer the
hospitality parameters for the PMS. These assignments must be coordinated with
the PMS vendor and the customer. On Page 1, administer the following:
hospitality parameters for the PMS. These assignments must be coordinated with
the PMS vendor and the customer. On Page 1, administer the following:
■
For the
Message Waiting Configuration
field, enter act-nopms if
the INTUITY is controlling the message waiting lamps, and enter act-pms
if the PMS is controlling the message waiting lamps. If the PMS supports
text messaging, enter act-pms. If all messaging is handled on the INTUITY
system, enter act-nopms.
if the PMS is controlling the message waiting lamps. If the PMS supports
text messaging, enter act-pms. If all messaging is handled on the INTUITY
system, enter act-nopms.
■
The
Controlled Restrictions Configuration
,
Housekeeper
Information Configuration
, and
Client Room Coverage Path
Configuration
fields control features offered by some PMS vendors. If
the PMS vendor supports the feature, enter act-pms in the corresponding
field. If the PMS vendor does not support the feature, enter act-nopms in
the corresponding field. Note that if the
field. If the PMS vendor does not support the feature, enter act-nopms in
the corresponding field. Note that if the
Client Room Coverage Path
Configuration
field is administered incorrectly, administered coverage
paths for rooms will be deleted.
■
In the
PMS Endpoint
field, enter the extension number of the PMS data
module for a DCP link.