Installing the System 
43
Connecting the Hospitality Adjuncts 
Stand-alone Call Accounting System Link
Using the DCE Port
This connection is used to transfer CDR information to a stand-alone call 
accounting system. This connection is valid for a 
csi or si system.
Parts List
The DCE port on the switch (this port is found on the Processor Interface 
Cable of a 
csi system labeled as J2)
One M25A or M25B cable plus gender changers as needed (or 
equivalent 25-pin straight-through cable) to connect from the DCE port to 
the interface port on the call accounting system.
Distance Limits
The distance limit from the switch to the stand-alone call accounting system is 50 
feet (15.2 meters). If the distance from the switch and the call accounting system 
is more than 50 feet (15.2 meters), or if the switch is an 
r system, see 
Cabling Diagram
 shows the connection between the DCE port on a 
csi or si system and a 
stand-alone call accounting system.
Figure 14. Switch-to-Call Accounting Link (Stand-Alone Call Accounting 
System)
DCE (si)
DCE (J2) (csi)
Switch
50 Ft. Maximum
Standalone
Call Accounting
Call
Accounting
Port
Demarcation
Point
M25A or M25B
RS232 Cable
«
eia2gca.cdr