Avaya 555-231-743 사용자 설명서

다운로드
페이지 274
GuestWorks and DEFINITY ECS Release 9
Technician Handbook for Hospitality Installations  
555-231-743  
Issue 1
November 2000
Installing the System 
69
Connecting the Hospitality Adjuncts 
Test Procedure 
Using the RS232 Mini-Tester (see the Note on 
), check the status of the 
connection at the data module. The leads marked with an asterisk are controlled 
by the switch, and the printer controls the other leads. Translations for this 
connection begin on 
.
!
CAUTION:
After using a mini-tester to check data leads, you MUST remove the 
mini-tester from the connection. DO NOT leave the mini-tester in-line during 
actual operation.
With the mini-tester connected to only the data module, the mini-tester should 
show the following:
NOTE:
RTS will be lit on the front panel of the 7400A or 7400B. The CTS lead 
shows green when used with an 8400B.
With the mini-tester connected to only the printer, the mini-tester should show the 
following:
TD
RTS
DTR
RD*
CTS*
DSR*
CD*
red
dark
dark
red
red
red
dark
TD
RTS
DTR
RD*
CTS*
DSR*
CD*
dark
red
green
dark
dark
dark
green