DELL 7.4 사용자 설명서

다운로드
페이지 232
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
101
Event ID — 2165
Description
The RAID controller firmware and driver validation was not performed. The 
configuration file cannot be opened.
Severity
Warning / Non-critical
Cause and 
Action
Cause: Storage Management is unable to determine whether the system has the 
minimum required versions of the RAID controller firmware and drivers. This 
situation may occur for a variety of reasons. For example, the installation directory 
path to the configuration file may not be correct. The configuration file may also 
have been removed or renamed.
Action: Reinstall Storage Management
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap 
Numbers
753
Event ID — 2166
Description
The RAID controller firmware and driver validation was not performed. The 
configuration file is out of date, missing the required information, or not properly 
formatted to complete the comparison.
Severity
Warning / Non-critical
Cause and 
Action
Cause: Storage Management is unable to determine whether the system has the 
minimum required versions of the RAID controller firmware and drivers. This 
situation has occurred because a configuration file is out of date, missing the 
required information, or not properly formatted to complete the comparison.
Action: Reinstall Storage Management.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2060
SNMP Trap 
Numbers
753
Event ID — 2167
Description
The current kernel version and the non-RAID SCSI driver version are older than the 
minimum required levels. See readme.txt for a list of validated kernel and driver 
versions.
96