Functions 
 
3.14 Integrated manual local control 
M200D AS-Interface Basic 
Manual, 03/2009, A5E01668085-01 
45
 
Keypad   
The keypad has four pushbuttons arranged in a square. 
 
 
Note 
They are only active when the key-operated switch is set to manual mode. 
 
 
Figure 3-7 
Keypad 
 
Pushbutton 
Meaning 
Function 
 
Continuous 
operation / jog 
mode   
The mode switches every time you press this pushbutton (continuous / jog). 
"Continuous" mode is indicated via the corresponding LED (yellow, lit up) (in 
manual mode only). 
When manual mode is deactivated, jog mode is reset. 
 
Quick stop 
DISABLE   
The "QUICK STOP" input actions are deactivated for all inputs. 
This pushbutton is active in jog mode and continuous operation. In continuous 
operation, the "QUICK STOP DISABLE" function can be activated by pressing the 
pushbutton once and deactivated by pressing it again. 
The yellow LED lights up regardless of the operating mode (as long as the function 
is active).  
 
Clockwise 
rotation   
The main circuit for CW operation is activated. 
In continuous operation, the main circuit can be activated by pressing the 
pushbutton once and deactivated by pressing it again.  
With reversing starters, an ongoing action can also be interrupted in continuous 
operation by pressing the "CCW rotation" pushbutton.  
The green LED lights up regardless of the operating mode (as long as the selected 
function is active).  
 
CCW rotation   
This pushbutton is only enabled for reversing starters. 
The main circuit for CCW operation is activated. 
In continuous operation, the main circuit can be activated by pressing the 
pushbutton once and deactivated by pressing it again.  
In continuous operation, an ongoing action can also be interrupted by pressing the 
"CCW rotation" pushbutton. 
The green LED lights up regardless of the operating mode (as long as the selected 
function is active).