Before Beginning Repair
3A2798D
13
Before Beginning Repair
Maintenance Procedures
Platen Maintenance
See F
IG
. 10. If the platen does not come out of the pail 
easily when the pump is being raised, the air assist 
tube (EF) or air assist check valve may be plugged, or 
the bleed stick (J) may not be tightened. A plugged air 
assist check valve prevents air from reaching the under-
side of the plate to assist in raising it from the pail. If the 
bleed stick is not tightened no pressure will build.
1.
Follow thPressure Relief Procedure on page 10. 
Refer to platen parts illustration on page 28 and dis-
assemble air assist check valve (414) as shown. 
2.
Clear air assist tube (EF) in platen. Clean all parts of 
air assist check valve (414) and reassemble.
3.
Remove bleed stick (J) from platen. Push bleed 
stick through bleed relieve ports to remove material 
residue. 
Adjust Spacers
Use Platen with Tapered and Straight Sided 
Pails
Use platen with tapered pails
1.
Working from the bottom, use screwdriver to pry 
spacer (EG) loose. Work spacer upward completely 
above the flange of the platen. See F
IG
. 11. 
2.
By hand, angle spacer (EG) and work it off the plate, 
pulling it down over the flange. See F
IG
. 12. 
3.
Save spacer (EG), as it is required for other applica-
tions.
To reduce the risk of serious injury whenever you are 
instructed to relieve pressure, always follow the 
Pressure Relief procedure.