Logs
The 36CDV logs are shipped in place. If a log is bro-
ken, refer to the replacement parts list for a replace-
ment. Figure 58 shows where the logs are secured to 
the fireplace.
RN/RP & EN/EP Models
For units equipped with “HI/LO” valves the flame 
adjustment is accomplished by rotating the “HI/LO” 
adjustment knob located near the center of the gas 
control valve. (Figs. 59)
Flame & Temperature Adjustment
It is important to periodically perform a visual check 
of the pilot and burner flames. Compare them to the  
illustrations. (Figs. 60 & 61)
If the flame patterns appear abnormal contact a 
qualified service provider for service and adjustment.
Flame Characteristics
LO
 
HI
 
FP390
FLAME ADJUSTMENT KNOB
11/21/96
Turn 
counterclockwise
to increase
flame height
Turn clockwise
to decrease
flame height
SIT 820 Valve
Fig. 59  Flame adjustment knob for SIT valve.
SIT RN/RP
FP1541
Fig. 60  Correct pilot flame appearance.
������
����������������
����
������
�����������
������
Log Rear
The log rear is 
secured to the back 
of the fireplace.
The log front is se-
cured to the 
bottom 
of the fireplace.
Ceramic 
Hearth 
Ember
Log Front
LG441
Fig. 58  36CDV logs.
������
�����������������
������
Red Glow,
Yellow Tips
LG442
Fig. 61  36CDV burner flame appearance.
Yellow Flame