Vermont Casting DVT38IN 사용자 설명서

다운로드
페이지 48
13
Chateau™
20011956
����
���
FP1821
set temp
9/07
����
���
����
����
����
����
����
����
�����
To Change the Set Temperature
Press and hold the SET key until the desired set tem-
perature is reached. (By pressing and holding the set 
key, the LCD screen set numbers will increase from 45° 
to 99°, then restart at 45°) 
Release the SET key. The LCD screen will display the set 
temperature for 3 seconds, then will flash the set tem-
perature for 3 seconds, then the LCD screen will default 
to display the room temperature.
To Disengage Thermostatic Mode
Press and release the MODE key or press the OFF 
CONTINUOUS PILOT key to disengage the thermostatic 
mode. The word “ROOM” on the LCD screen will not 
show when the thermostatic mode is not in operation.
NOTE: The highest SET temperature is 99° Fahrenheit 
(32° Celsius) and the lowest temperature is 45° Fahren-
heit (6° Celsius).
CONTINUOUS PILOT FEATURE
This feature allows you to change from a spark to pilot 
system to a standing pilot system for appliances during 
Cold Climate to keep the firebox warm.
To operate the CONTINUOUS PILOT FEATURE do the 
following:
On or Off Operation
Press and hold the OFF CONTINUOUS PILOT key for 
approximately 5 seconds, until the word “PILOT” appears 
on the LCD screen.
NOTE: The word “PILOT” will appear on the LCD screen 
in ON mode.
CP (CHILDPROOF) FEATURE
This SKYTECH remote control includes a CHILDPROOF 
“LOCK-OUT” feature that allows the user to “LOCK-OUT” 
operation of the appliance from the transmitter.
SETTING “LOCK-OUT” - (CP)
  To activate the “LOCK-OUT” feature, press and hold 
the ON H/L key and the MODE key at the same time 
for 5 seconds. The letters “CP” will appear in the 
TEMP frame on the LCD screen.
  To disengage the “LOCK-OUT”, press and hold the 
ON H/L key and the MODE key at the same time for 
5 seconds and the letters “CP” will disappear from 
the LCD screen and the transmitter will return to its 
normal operating condition.
  To verify the transmitter is in the CP lock-out mode, 
press any key and the LCD screen will show “CP”.
NOTE: If the appliance is already operating in the ON or THERMOSTATIC modes, engaging the “LOCK-OUT” will not 
cancel the operating mode. Engaging the “LOCK-OUT” prevents only the manual operation of the transmitter. If in the 
auto modes, the THERMOSTATIC operation will continue to operate normally. To totally “LOCK-OUT” the operation of 
the transmitter’s operating signals; the transmitter’s mode must be set to OFF.