Vermont Casting DVT38IN 사용자 설명서

다운로드
페이지 48
35
Chateau™
20011956
Lighting & Operating Instructions
For Fireplaces equipped with American Flame Automatic Control System (IN  or IP)
A.  This fireplace is equipped with an ignition device 
which automatically lights the pilot and main burner. 
The pilot and burner light automatically with the hand 
held remote control only. DO NOT try to light the 
pilot by hand. Before lighting this appliance, follow 
these instructions exactly.
B.  BEFORE OPERATING, smell all around the 
appliance area for gas. Be sure to smell next to  
the floor because some gas is heavier than the air 
and will settle on the floor.
What to do if you smell gas
•  Do not try to light any appliance.
For Your Safety, Read the Following Warnings  
before Lighting the Appliance
•  Do not operate any electrical switch.
•  Do not use any phone in your building.
•  Immediately call your gas supplier from a 
neighbor’s phone. Follow the gas suppliers 
instructions.
•  If you cannot contact your gas supplier call the 
Fire Department
C. Do not use this appliance  if any part has been under 
water. Immediately call a qualified service technician 
to inspect the appliance and replace any part of the 
control system and any gas control that has been 
under water.
  1.   Turn the wireless remote to the OFF position.
  2.   Turn OFF all electrical power to the fireplace if  
    service is required.
  3.  Turn the shut-off valve on the gas supply line to  
    the OFF position.
FP297A
     
Warning:
  If you do not follow these instructions exactly, a fire or explosion may  
     
  result, causing property damage, personal injury and loss of life.
Lighting Instructions
Turning Off the Gas to the Appliance
1.  STOP! Read the safety information above before 
continuing.
2.  Turn off all electrical power to the appliance.
3.  This appliance is equipped with an ignition device 
which  automatically lights the pilot. DO NOT try to 
light the pilot by hand.
4.  Turn the wireless remote OFF.
5.  Wait five (5) minutes to clear out any gas. 
Then smell for gas, including near the floor. 
If you smell gas, STOP. Follow instruction B 
in the safety warnings above. If you do not 
smell gas, go on to the next step.
6.  Turn ON all electrical power to the 
appliance.
7.  Turn wireless remote ON.
9.  If the appliance will not operate, follow the 
instructions TURNING OFF THE GAS TO 
THE APPLIANCE, and call your service 
technician or gas supplier.
FP297A
INSTA VENT FREE
UVHB26 GAS SUPPLY 
7/1/98
1/2” Gas Supply
1/2” NPT X 1/2” Flare 
Shut-off Valve
1/2” Gas Tight or 
Tinned Copper 
(from valve)
(Not provided)
������
������������
����
“S” Connection 
Connect to Module
Spark to Pilot
Pilot Assembly
Pilot Gas 
Connection Side or Back
“I” Connection
Connect to 
Module
Main Valve Internal Solenoid 
Connection 
Green & White Wires
Pilot Internal Solenoid 
Connection
Orange & White Wires
Pilot 
Adjustment 
Screw 
Motor Wires
Black Plastic Cap
Minimum Rate 
Screw
Motor Drive