Vermont Casting DVT38IN 사용자 설명서

다운로드
페이지 48
41
Chateau™
20011956
Pilot Flame Adjustment
Typically, the top 3/8” or 1/2” of the pilot flame sensor 
should be engulfed in the pilot flame. (Page 33, Fig. 55)
To adjust pilot burner:
1.  Locate pilot adjustment screw on the valve next to 
the black plastic cap. Refer to Page 35.
2.  Adjust pilot screw to provide proper sized flame. 
Only a small adjustment should be needed.
NOTE: Do not rotate screw excessively. Do not adjust 
any other screws on the valve.
 
Conversion to LP
 
Burner Orifice 
Input (BTU/hr) 
 
Kit # 
Model 
Front 
Part # 
Middle 
Part # 
Rear  
Part # 
Minimum  Maximum
  20011992 
DVT38IP 
#66 
20009182 
#59 
20000664 
#50 
30000337 
34,000 
46,000 
 
 
 
(.033”) 
 
(.041”) 
 
(.070”)
  20012367 
DVT44IP 
#63 
20006251 
#57 
20004587 
#49 
20006252 
45,000 
60,000 
 
 
 
(.037”) 
 
(.043”) 
 
(.073”) 
Table 1  Injector Orifice Size Matrix
Conversion to LP
 
 
Burner Tube 
Burner Housing
 
Model 
Air Shutter Setting 
 Air Shutter Setting
 
DVT38IP 
Fully open 
n/a
 
DVT44IP 
Fully open 
Fully open
Table 2 Air Shutter Settings
2
Table 3 Valve Minimum Rate Screw
 
Model 
Size 
Part #
 
DVT38IP 
#31 (.120”) 
20012364
 
DVT44IP 
No Shank Screw 
20012264