Polycom SIP 2.2.0 사용자 설명서

다운로드
페이지 254
Administrator’s Guide SoundPoint IP / SoundStation IP 
A - 72
Scheduled Logging Parameters <sched/>
The phone can be configured to schedule certain advanced logging tasks on a 
periodic basis. These attributes should be set in consultation with Polycom 
Technical Support. Each scheduled log task is controlled by a unique attribute 
set starting with log.sched.x where x identifies the task.
log.render.file.size
positive 
integer, 1 to 
179.5
16
Maximum local application log file 
size in Kbytes. When this size is 
exceeded, the file is uploaded to 
the boot server and the local copy 
is erased.
log.render.file.upload.period
positive 
integer
172800
Time in seconds between log file 
uploads to the boot server.
Note: The log file will not be 
uploaded if no new events have 
been logged since the last upload
.
log.render.file.upload.append
0, 1
1
If set to 1, use append mode when 
uploading log files to server.
Note: HTTP and TFTP don’t 
support append mode unless the 
server is set up for this
.
log.render.file.upload.append.sizeLimit
positive 
integer
512
Maximum log file size on boot 
server in Kbytes.
log.render.file.upload.append.limitMode
delete, stop
delete
Behavior when server log file has 
reached its limit. 
delete=delete file and start over 
stop=stop appending to file
Attribute
Permitted 
Values
Default
Interpretation
Attribute
Permitted 
Values
Interpretation
log.sched.x.name
alphanumeric 
string
Name of an internal system command to be periodically executed. 
To be supplied by Polycom.
log.sched.x.level
0-5
Event class to assign to the log events generated by this command. 
This needs to be the same or higher than log.level.change.slog for 
these events to appear in the log.
log.sched.x.period
positive 
integer
Seconds between each command execution. 0=run once