Polycom SIP 2.2.0 사용자 설명서

다운로드
페이지 254
 Configuration Files
A - 85
reg.x.ringType
1 to 22
2
The ringer to be used for calls received by 
this registration. Default is the first non-silent 
ringer.
reg.x.lineKeys
1 to max
1
max = the number of line keys on the phone. 
max = 1 on SoundStation IP 4000,
max = 2 on IP 301, 320, 330, 430,
max = 3 on IP 501, 
max = 4 on IP 550,
max = 6 on IP 600,
max = 48 on IP 601, 650 (without any 
Expansion Modules attached, only 6 line keys 
are available)
The number of line keys on the phone to be 
associated with registration ‘x’.
reg.x.callsPerLineKey
1 to 24 OR
1 to 8
24 OR
8
For the SoundPoint IP 600, 601, and 650 the 
permitted range is 1 to 24 and the default is 
24.
For all other phones the permitted range is 1 
to 8 and the default is 8. 
This is the number of calls or conferences 
which may be active or on hold per line key 
associated with this registration. 
Note that this overrides 
call.callsPerLineKey
 for this registration. 
Refer to 
 
on page 
reg.x.outboundProxy.address
dotted-decimal IP 
address or host 
name
Null
IP address or host name and port of a SIP 
server to which the phone shall send all 
requests.
reg.x.outboundProxy.port
1 to 65535
5060
Attribute
Permitted 
Values
Default
Interpretation