MAINTENANCE 
86037500 PJ2A 03/04/08 
 
 4-1
DAILY MAINTENANCE 
1.  Vacuum unused cleaning solution from solution tank into recovery bucket. 
2.  Flush two gallons of clean water through pumping system of extractor, PILEJOGGER and hand tools.  Twice 
a month, flush a vinegar solution (one quart white vinegar to two gallons water) or browning prevent solution 
(mixed as directed) through extractor and PILEJOGGER.  This will minimize buildup of alkaline residue in the 
system. 
3.  Remove carpet lint from brush fibers and underside of brush housing.  Flush out with water.   
4.  Check for carpet lint buildup in vac shoe.  Clean out and flush with water. 
5.  If spray jets become clogged, remove from manifold, wash and blow-dry to remove obstruction.  Do not use 
pins, wires, etc. to clean jets as this could destroy spray pattern. 
6.  Apply silicone lubricant to quick-disconnect fittings. 
 
TROUBLESHOOTING 
 
PROBLEM
CAUSE SOLUTION 
No power to brush 
Dead electrical circuit 
Check building circuit breaker or fuse box 
 
Faulty switch 
Replace 
 
Faulty electrical cable 
Replace 
Brush motor speed 
varies or doesn’t run 
Faulty motor 
Replace 
 
Faulty switch 
Replace 
Loss of vacuum 
Loose cuff on vac hose 
Tighten cuffs (turn counterclockwise) 
 
Vac chamber plugged 
Wash out with hose.  Pick lint out with wire. 
 
Broken vac hose 
Replace 
Solution hose quick 
disconnects hard to 
insert 
Corrosion on fittings 
Clean fitting by soaking in vinegar solution, lubricate 
lightly with silicon lube 
Solution won’t shut off 
Faulty solution valve 
Repair or replace 
Clogged spray jets 
Corrosion 
Clean with steel wool and vinegar solution; wipe dry 
after each use. 
Carpet not clean 
Severe soil conditions 
Make more than one pass at right angle to first pass.  
Prespray. 
Carpet too wet 
Loss of vacuum 
Check vac system for leaks 
 
WIRING DIAGRAM