Renesas SH7264 사용자 설명서
![Renesas](https://files.manualsbrain.com/attachments/59153266feca598c11e08bf1f143ccfcf45441a4/common/fit/150/50/d3d06de51d338eb4f916b44a9629f9d48697a59cd7344be40cf24bae01c5/brand_logo.gif)
Section 37 Electrical Characteristics
Page 1962 of 2108
R01UH0134EJ0400 Rev. 4.00
Sep
24,
2014
SH7262 Group, SH7264 Group
37.2
Power-On/Power-Off Sequence
The 1.2-V power supply (V
CC
, PLLV
CC
, USBAV
CC
, USBDV
CC
, and USBUV
CC
) and 3.3-V power
supply (PV
CC
, AV
CC
, USBAPV
CC
, and USBDPV
CC
) can be turned on and off in any order.
When turning on the power, be sure to drive both the
TRST and RES pins low; otherwise, the
output pins and input/output pins output undefined levels, resulting in system malfunction.
When turning off the power, drive the
TRST and RES pins low if the undefined output may cause
a problem.