Intel® Solid-State Drive DC P3700 Series 
 
Product Specification 
 
May 2015 
42 
 
330566-009US 
Appendix D  SMBUS Command Response on 
0x6A (NVMe Workgroup Defined) 
Table 38:  Command Response on 0x6A (NVMe Workgroup Defined) 
Command 
Code  
Offset 
(byte) 
Description 
00 
Length of Status: Indicates number of additional bytes to read before encountering PEC. 
This value should always be 6 (06h) in implementations of this version of the spec. 
01 
Status Flags (SFLGS): This field indicates the status of the NVM subsystem. 
SMBus Arbitration – Bit 7 is set ‘1’ after a SMBus block read is completed all the way  
to the stop bit without bus contention and cleared to ‘0’ if a SMBus Send Byte FFh is 
received on this SMBus slave address.  
Drive Not Ready – Bit 6 is set to ‘1’ when the subsystem cannot process NVMe 
management commands, and the rest of the transmission may be invalid.  If cleared  
to ‘0’, then the NVM subsystem is fully powered and ready to respond to management 
commands. This logic level intentionally identifies and prioritizes powered up and ready 
drives over their powered off neighbors on the same SMBus segment.   
Drive Functional – Bit 5 is set to ‘1’ to indicate an NVM subsystem is functional.  If  
cleared to ‘0’, then there is an unrecoverable failure in the NVM subsystem and the  
rest of the transmission may be invalid.  
Reset Not Required - Bit 4 is set to ‘1’ to indicate the NVM subsystem does not need  
a reset to resume normal operation. If cleared to ‘0’ then the NVM subsystem has 
experienced an error that prevents continued normal operation. A controller reset  
is required to resume normal operation. 
Port 0 PCIe Link Active - Bit 3 is set to ‘1’ to indicate the first port’s PCIe link is up  
(i.e., the Data Link Control and Management State Machine is in the DL_Active state).  
If cleared to ‘0’, then the PCIe link is down. 
Port 1 PCIe Link Active - Bit 2 is set to ‘1’ to indicate the second port’s PCIe link is up.  
If cleared to ‘0’, then the second port’s PCIe link is down or not present.  
Bits 1-0 shall be set to ‘1’.  
02 
SMART Warnings: This field shall contain the Critical Warning field (byte 0) of the NVMe 
SMART / Health Information log.  Each bit in this field shall be inverted from the NVMe 
definition (i.e., the management interface shall indicate a ‘0’ value while the 
corresponding bit is ‘1’ in the log page).  Refer to the NVMe specification for bit 
definitions. 
If there are multiple controllers in the NVM subsystem, the management endpoint shall 
combine the Critical Warning field from every controller such that a bit in this field is: 
 
Cleared to ‘0’ if any controller in the subsystem indicates a critical warning for that 
corresponding bit.  
Set to ‘1’ if all controllers in the NVM subsystem do not indicate a critical warning for the 
corresponding bit. 
03 
Composite Temperature (CTemp): This field indicates the current temperature in 
degrees Celsius.  If a temperature value is reported, it should be the same temperature as 
the Composite Temperature from the SMART log of hottest controller in the NVM 
subsystem. The reported temperature range is vendor specific, and shall not exceed the